Introduction: This study is intended to evaluate the feasibility of using a high-resolution pinhole SPECT system and iodine-123-N-isopropyl-4-iodoamphetamine ((123)I-IMP) for three-dimensional (3D) absolute quantitation of regional cerebral blood flow (rCBF) in mice.

Methods: The pinhole SPECT system consists of a rotating stage and a pinhole collimator attached to a clinical gamma camera. The collimator's focal length is 251 mm. Phantom studies were performed to evaluate sensitivity and full-width half-maximum (FWHM) spatial resolution. The aperture-to-object distance was 15 mm. Six mice were studied. Cerebral infarctions were induced by ligating and disconnecting the distal portion of the left middle cerebral artery. Ex vivo SPECT studies were performed using harvested brains and skulls. The CBF volumetric image was computed using the standardized input function.

Results: Excellent spatial resolution of 0.9-mm FWHM and uniform sensitivity throughout the 3D volume were demonstrated in the phantom experiments. The CBF images showed a defect in the infarcted areas and a reduction of CBF values in the infarcted region as compared with the control region.

Conclusions: This study demonstrated the feasibility of the 3D quantitation of rCBF in mice using a high-resolution pinhole SPECT system and (123)I-IMP.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.nucmedbio.2011.04.007DOI Listing

Publication Analysis

Top Keywords

pinhole spect
16
spect system
16
high-resolution pinhole
12
quantitation regional
8
regional cerebral
8
cerebral blood
8
blood flow
8
mice high-resolution
8
studies performed
8
spatial resolution
8

Similar Publications

Advanced pinhole collimation geometries optimized for preclinical high-energyimaging facilitate applications such asandemitter imaging, simultaneous multi-isotope PET and PET/SPECT, and positron range-free PET. These geometries replace each pinhole with a group of clustered pinholes (CPs) featuring smaller individual pinhole opening angles (POAs), enabling sub-mm resolution imaging up to ∼1 MeV. Further narrowing POAs while retaining field-of-view (FOV) may enhance high-energy imaging but faces geometrical constraints.

View Article and Find Full Text PDF

Purpose: Parathyroid imaging with dual-phase technetium-99m methoxyisobutrylizonitrile (Tc-99m MIBI) scintigraphy serves as an important prerequisite for the identification of hyperfunctioning parathyroid gland(s) in patients with primary hyperparathyroidism (PHPT) for a successful targeted parathyroidectomy. This study aimed to evaluate the clinical value of additional lateral imaging and single-photon emission computed tomography/computed tomography (SPECT/CT) versus conventional planar imaging for locating parathyroid pathologies in patients with PHPT.

Materials And Methods: A retrospective review was performed on 105 patients who underwent dual-phase Tc-99m MIBI scintigraphy and were surgically treated by parathyroidectomy.

View Article and Find Full Text PDF

Purpose: Collimator-detector response function (CDRF) of a SPECT scanner refers to the image generated from a point source of activity. This research aims to characterize the CDRF of a breast-dedicated SPECT imager equipped with a lofthole collimator using GATE Monte Carlo simulation.

Materials And Methods: To do so, a cylindrical multi-lofthole collimation system with lofthole apertures dedicated to breast imaging was modeled using the GATE Monte Carlo simulator.

View Article and Find Full Text PDF

Single-photon emission computed tomography (SPECT) with pinhole collimators can provide high-resolution imaging, but is often limited by low sensitivity. Acquiring projections simultaneously through multiple pinholes affords both high resolution and high sensitivity. However, the overlap of projections from different pinholes on detectors, known as multiplexing, has been shown to cause artefacts which degrade reconstructed images.

View Article and Find Full Text PDF

We investigated the feasibility of using a dopamine transporter (DaT) tracer ligand ([I]FP-CIT) along with novel multi-pinhole brain collimators for dynamic brain single photon emission computed tomography (SPECT) in suspected Parkinson's disease patients. Thirteen patients underwent dynamic tracer acquisitions before standard imaging. Uptake values were corrected for partial volume effects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!