The current-dependent beam divergence at a distance of 50 μm from an indium-liquid metal ion source is derived from experimental data obtained by measuring the beam spread with a 3D Plasma diagnostic system at a distance of 10 cm from the needle tip. The observed relationship between emission current and beam divergence in vicinity of the emitting needle is used to design a focusing electrode for a field-emission electric propulsion thruster operating at currents up to 150 μA. Another application involves focused ion beam columns which may choose to forego a beam-limiting aperture, such as LMIS-based rapid machining tools with large beam currents.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultramic.2011.01.040 | DOI Listing |
Ultrason Imaging
January 2025
Biomedical Ultrasound Imaging Laboratory, Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology, Madras, Chennai, India.
Imaging depth remains a restriction for Synthetic Aperture (SA) approaches, even though SA techniques have been shown to overcome some of the drawbacks of Conventional Focused Beamforming (CFB) technique. This limitation is attributed to lesser energy per transmit in SA techniques compared to that of CFB technique. Therefore, in this paper, a systematic investigation is done to evaluate the improvement in imaging depth and image quality of B-mode ultrasound images in the case of SA technique using PZT transducer by boosting the input voltage to the transducer, while measuring the acoustic exposure parameters recommended in international standards.
View Article and Find Full Text PDFInt J Drug Policy
December 2024
Peter Boris Centre for Addictions Research, St. Joseph's Healthcare Hamilton and McMaster University, Canada; Michael G. DeGroote Centre for Medicinal Cannabis Research, McMaster University and St. Joseph's Healthcare Hamilton, Canada.
Background: Recreational cannabis legalization marked a significant policy shift in Canada, but has been difficult to evaluate because of the absence of a control group. Although it is unfeasible to evaluate legalization using a randomized controlled trial design, sophisticated statistical techniques can employ quasi-experimental designs using natural experiments. This study evaluates the impact of cannabis legalization in a longitudinal cohort of Canadian emerging adults by comparing changes in cannabis use frequency and related consequences over time to changes in a similar cohort in a United States jurisdiction where no policy change took place.
View Article and Find Full Text PDFBMC Oral Health
December 2024
Department of Oral and Maxillofacial Radiology, Necmettin Erbakan University, Faculty of Dentistry, Konya, Turkey.
Background: Knowledge of root and canal morphology is a prerequisite for effective nonsurgical and surgical endodontic treatments. The aim of this cone beam computed tomography (CBCT) study was to evaluate the root canal morphology of permanent canines in a Turkish subpopulation using two classification systems.
Methods: A total of 2,000 canine teeth were examined.
Med Phys
December 2024
State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, China.
Background: One big challenge in the noninvasive high-intensity focused ultrasound (HIFU) surgery is that the location and shape of its focus is unpredictable at the preoperative stage due to the complexity of sound wave propagation. The Acoustic Radiation Force Impulse (ARFI) imaging is a potential solution to this problem, but artifacts resulting from shear wave propagation remain to be solved.
Purpose: In this study, we proposed avoiding those artefacts by applying the ARFI technique at a high imaging frame rate within a very short time before the shear waves start to propagate.
Ultrasonics
November 2024
Biomedical Ultrasound Laboratory, Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, India. Electronic address:
Quasi-static elastography (QSE) is a well-established technique used in medical imaging, where ultrasound data is collected both, before and after applying a slight compression on a tissue. This data is then analyzed to create image frames that reveal the stiffness parameter of the underlying tissue medium. Previous studies have focused on assessing how the Conventional Focused Beam (CFB) transmit method impacts the ultrasound elastography image quality.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!