A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Deep ablation and depth profiling by laser-induced breakdown spectroscopy (LIBS) employing multi-pulse laser excitation: application to galvanized steel. | LitMetric

The potential of a multi-pulse (MP) laser excitation scheme for deep stratigraphy of electrolytically galvanized steel using laser-induced breakdown spectrometry (LIBS) has been evaluated. For this purpose, a commercial electro-optically (EO) Q-switched Nd:YAG laser was employed, where by reducing the delay between the Q-switch opening and the flash lamp, a train of pulses (up to 11) separated by approximately 7.40 μs was generated during one lamp flashing. Plasma emission after each individual laser pulse of the MP sequence was detected by a spectrograph equipped with an intensified charge-coupled device (iCCD) detector. With MP excitation, the ablation efficiency was increased ten-fold on iron sample and 22.5-fold on zinc material with respect to dual-pulse or single-pulse excitation. The LIBS signal generated by MP excitation shows an analogous enhancement. Although the total energy per shot delivered to samples was only 60 mJ, it was possible using LIBS to measure the sample stratigraphy up to depths of 90 μm on zinc-coated steel sheets. A satisfactory agreement between the Zn thickness determined by the MP-LIBS system and data from the manufacturer has also been obtained.

Download full-text PDF

Source
http://dx.doi.org/10.1366/11-06242DOI Listing

Publication Analysis

Top Keywords

laser-induced breakdown
8
multi-pulse laser
8
laser excitation
8
galvanized steel
8
excitation
5
deep ablation
4
ablation depth
4
depth profiling
4
profiling laser-induced
4
breakdown spectroscopy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!