Recently, transmission Raman spectroscopy has been shown to be a valuable tool in the volumetric quantification of pharmaceutical formulations. In this work a Monte Carlo simulation and experimental study are performed to elucidate the dependence of the Raman signal on depth from the viewpoint of probing pharmaceutical tablets and powders in this experimental configuration. The transmission Raman signal is shown to exhibit a moderate bias toward the center of the tablets and this can be considerably reduced by using a recently developed Raman signal-enhancing concept, the "photon diode." The enhancing element not only reduces the bias but also increases the overall Raman signal intensity and consequently improves the signal-to-noise ratio of the measured spectrum. Overall, its implementation with appropriately chosen reflectivity results in a more uniform volumetric sampling across the half of the tablet where the photon diode is used (or across the tablet's entire depth if two photon diodes are used on each side of tablet) and enhanced overall sensitivity. These findings are substantiated experimentally on a segmented tablet by inserting a poly(ethelyne terephthalate) (PET) film doped with TiO(2) at different depths and monitoring its contribution to the overall transmission Raman signal from the segmented tablet. The numerical simulations also indicate considerable sensitivity of the overall Raman signal to the absorption of the sample, which is in line with large migration distances traversed by photons in these measurements. The presence of sample absorption was shown numerically to reduce the signal enhancement effect while the overall depth-dependence profile remained broadly unchanged. The absorption was also shown to produce a depth profile with the photon diode similar to that without it, although with a reduced absolute intensity of Raman signals and diminished enhancement effect.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1366/11-06259 | DOI Listing |
Nanoscale
January 2025
Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad, Kerala 678 557, India.
Chemotherapy is a crucial cancer treatment, but its effectiveness requires precise monitoring of drug concentrations in patients. This study introduces an innovative electrochemical strip sensor design to detect and continuously monitor methotrexate (MTX), a key chemotherapeutic drug. The sensor is crafted through an eco-friendly synthesis process that produces porous reduced graphene oxide (PrGO), which is then integrated with gold nanocomposites and polypyrrole (PPy) to boost the performance of a screen-printed carbon electrode (SPCE).
View Article and Find Full Text PDFSoft Matter
January 2025
Faculty of Chemistry, Ho Chi Minh City University of Science, Vietnam National University, Ho Chi Minh City, 227 Nguyen Van Cu Street, Ward 4, District 5, Ho Chi Minh City 70000, Vietnam.
Surface-enhanced Raman spectroscopy (SERS) is a highly sensitive analytical technique with excellent molecular specificity. However, separate pristine nanoparticles produce relatively weak Raman signals. It is necessary to focus on increasing the "hot-spot" density generated at the nanogaps between the adjacent nanoparticles (second-generation SERS hotspot), thus significantly boosting the Raman signal by creating an electromagnetic field.
View Article and Find Full Text PDFPhys Chem Chem Phys
January 2025
Forschungszentrum Jülich, Institute of Energy Technologies - Fundamental Electrochemistry (IET-1), Jülich, Germany.
The study of degradation behavior of electrocatalysts in an industrial context calls for rapid and efficient analysis methods. Optical methods like Raman spectroscopy fulfil these requirements and are thus predestined for this purpose. However, the iridium utilized in proton exchange membrane electrolysis (PEMEL) is Raman inactive in its metallic state.
View Article and Find Full Text PDFAnal Chem
January 2025
State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, PR China.
An entropy-driven catalysis (EDC) strategy is appealing for amplified bioimaging of microRNAs in living cells; yet, complex operation procedures, lacking of cell selectivity, and insufficient accuracy hamper its further applications. Here, we introduce an ingenious all-in-one entropy-driven DNA nanomachine (termed as AIO-EDN), which can be triggered by endogenous apurinic/apyrimidinic endonuclease 1 (APE1) to achieve tumor cell-selective dual-mode imaging of microRNA. Compared with the traditional EDC strategy, the integrated design of AIO-EDN achieves autocatalytic signal amplification without extra fuel strands.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
January 2025
Institute of Organic Chemistry and Biochemistry, Czech Academy of Sciences, 160 00 Prague, Czech Republic. Electronic address:
Model P-chirogenic phosphonates derived from isopinocampheol, offering an excellent experimental system for studying chirality on the phosphorus chiral center, were studied using a set of chiroptical methods including ECD, VCD and ROA. Thanks to their rigidity, limiting the number of possible conformers, we successfully correlated the experimental UV-vis/ECD, IR/VCD and Raman/ROA results with DFT calculations. This allowed us to confidently assign the absolute configuration of our models, and our assignment is consistent with X-ray diffraction (XRD) data.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!