Evaluation of the SEDline to improve the safety and efficiency of conscious sedation.

Proc (Bayl Univ Med Cent)

Department of Periodontology, Baylor College of Dentistry, Texas A&M University Health Science Center (Caputo, Rossmann, Beach, Meyrat, Barnes, Kerns, Crump, Bookatz, Ezzo); the Department of Anesthesiology and Pain Management, Baylor University Medical Center at Dallas (Ramsay); and the Veterans Affairs Medical Center Dental Service, Dallas, TX (Griffiths). Dr. Caputo is now in private practice in Castle Rock, Colorado.

Published: July 2011

Brain function monitors have improved safety and efficiency in general anesthesia; however, they have not been adequately tested for guiding conscious sedation for periodontal surgical procedures. This study evaluated the patient state index (PSI) obtained from the SEDline monitor (Sedline Inc., San Diego, CA) to determine its capacity to improve the safety and efficiency of intravenous conscious sedation during outpatient periodontal surgery. Twenty-one patients at the periodontics clinic of Baylor College of Dentistry were admitted to the study in 2009 and sedated to a moderate level using midazolam and fentanyl during periodontal surgery. The PSI monitoring was blinded from the clinician, and the following data were collected: vital signs, Ramsay sedation scale (RSS), medications administered, adverse events, PSI, electroencephalography, and the patients' perspective through visual analogue scales. The data were correlated to evaluate the PSI's ability to assess the level of sedation. Results showed that the RSS and PSI did not correlate (r = -0.25) unless high values associated with electromyographical (EMG) activity were corrected (r = -0.47). Oxygen desaturation did not correlate with the PSI (r = -0.08). Satisfaction (r = -0.57) and amnesia (r = -0.55) both increased as the average PSI decreased. In conclusion, within the limits of this study, PSI appears to correlate with amnesia, allowing a practitioner to titrate medications to that effect. It did not provide advance warning of adverse events and had inherent inaccuracies due to EMG activity during oral surgery. The PSI has the potential to increase safety and efficiency in conscious sedation but requires further development to eliminate EMG activity from confounding the score.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3124903PMC
http://dx.doi.org/10.1080/08998280.2011.11928715DOI Listing

Publication Analysis

Top Keywords

safety efficiency
16
conscious sedation
16
emg activity
12
improve safety
8
efficiency conscious
8
psi
8
periodontal surgery
8
surgery psi
8
adverse events
8
sedation
6

Similar Publications

Aim: This study aimed to explore the emotions of operating room nurses in Japan towards perioperative nursing using generative AI and human analysis, and to identify factors contributing to burnout and turnover.

Methods: A single-center cross-sectional study was conducted from February 2023 to February 2024, involving semi-structured interviews with 10 operating room nurses from a national hospital in Japan. Interview transcripts were analyzed using generative AI (ChatGPT-4o) and human researchers for thematic, emotional, and subjectivity analysis.

View Article and Find Full Text PDF

Formulation and adjuvant technologies can facilitate the use of insecticides that have higher biological efficiency application features. Safety, physicochemical properties by increasing consumer demand for safe food and enhancing operator safety. The aim of this current work was to develop a green efficient, and stable pesticide formulation.

View Article and Find Full Text PDF

Drums are the core working mechanism of the coal mining machine for coal mining. The structural design level of the drum is crucial for mining efficiency and safety production. Traditional design methods not only have long design cycles and high costs, but also limited design capabilities.

View Article and Find Full Text PDF

This study investigates the feasibility of using nano-thermal rod for deicing tunnel pavements in cold region. The heating performance of the nano-thermal rod was compared with that of carbon fiber heating wire under low voltage conditions. Experimental studies were conducted in a controlled environmental chamber to evaluate the effects of arrangement parameters (spacing, buried depth, input power) and environmental factors (ambient temperature and moisture) on heating rate and effectiveness.

View Article and Find Full Text PDF

The correct choice of a stone aggregate for railway ballast is directly related to the stability, safety, efficiency, and maintenance costs of the track. The aggregate must meet several criteria to ensure it is the most appropriate material. Thus, the present study aimed to evaluate four distinct stones: two granites, a diabase, and a basalt, all mined in the eastern region of the state of São Paulo, Brazil, regarding their applicability as ballast.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?