A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of hyoid and laryngeal displacement in video fluoroscopic swallowing studies: variability, reliability, and measurement error. | LitMetric

Measurement of hyoid and laryngeal displacement in video fluoroscopic swallowing studies: variability, reliability, and measurement error.

Dysphagia

Department of Speech, Language, and Hearing Sciences, College of Public Health and Health Professions, University of Florida, Gainesville, FL 32610-0174, USA.

Published: June 2012

Video fluoroscopy is commonly used in the study of swallowing kinematics. However, various procedures used in linear measurements obtained from video fluoroscopy may contribute to increased variability or measurement error. This study evaluated the influence of calibration referent and image rotation on measurement variability for hyoid and laryngeal displacement during swallowing. Inter- and intrarater reliabilities were also estimated for hyoid and laryngeal displacement measurements across conditions. The use of different calibration referents did not contribute significantly to variability in measures of hyoid and laryngeal displacement but image rotation affected horizontal measures for both structures. Inter- and intrarater reliabilities were high. Using the 95% confidence interval as the error index, measurement error was estimated to range from 2.48 to 3.06 mm. These results address procedural decisions for measuring hyoid and laryngeal displacement in video fluoroscopic swallowing studies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00455-011-9352-2DOI Listing

Publication Analysis

Top Keywords

hyoid laryngeal
20
laryngeal displacement
20
measurement error
12
displacement video
8
video fluoroscopic
8
fluoroscopic swallowing
8
swallowing studies
8
video fluoroscopy
8
image rotation
8
inter- intrarater
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!