A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Site-to-site variation of muscle activity and sensitivity in the human anterior temporalis muscle: implications for contingent stimulation. | LitMetric

Objective: To evaluate variation of electromyographic (EMG) activity and sensitivity between different sites of anterior temporalis (AT) muscle.

Materials And Methods: Sixteen healthy subjects (eight men: 28.8 ± 5.2 year old and eight women: 29.1 ± 3.9) participated in one experimental session. EMG activity during masticatory muscle contraction was recorded from nine sites at the AT muscle in a 3 × 3 grid with 1 cm between. The subjects maintained steady 30% of maximal voluntary contraction (MVC) using visual feedback. The surface EMG electrode was moved sequentially between these nine test sites and the contractions were repeated. One site was tested four times to assess test-re-test variability. The sensory threshold to electrical stimulation and impedance was also measured at the same sites as the placement of EMG electrodes.

Results: The 30% MVC force values did not differ between sites (p = 0.863) or within the same site (p = 0.995) due to the feedback. The EMG activity during 30% MVC was highest at the anterior-superior site (p < 0.05) with a marginal difference within the same site (p = 0.044). Impedance was higher at the posterior-superior, posterior-middle and posterior-inferior sites (p < 0.05). The sensory threshold was highest at the posterior-superior site (p < 0.05).

Conclusion: These findings showed that electrodes close to the hairline have higher impedance and sensory thresholds and should be avoided. The anterior-superior site produces the highest EMG activity and lower sensory thresholds and can be recommended as the optimal site to place the electrode for contingent stimulation.

Download full-text PDF

Source
http://dx.doi.org/10.3109/00016357.2011.597778DOI Listing

Publication Analysis

Top Keywords

emg activity
16
activity sensitivity
8
anterior temporalis
8
contingent stimulation
8
sensory threshold
8
30% mvc
8
anterior-superior site
8
sensory thresholds
8
site
7
emg
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!