A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Control design and implementation of a novel master-slave surgery robot system, MicroHand A. | LitMetric

Background: Compared with conventional minimally invasive surgery and open surgery, robotic-assisted minimally invasive surgery can overcome or eliminate drawbacks caused by operator restrictions, motion limitation by the trocar and the image system, such as fatigue, trembling, low precision, constrained degree-of-freedom, poor hand-eye coordination and restricted surgical vision. In this paper, a novel partly tendon-driven master-slave robot system is proposed to assist minimally invasive surgery and a master-slave control architecture is developed for abdominal surgical operations.

Methods: A novel master-slave surgery robot system named MicroHand A has been developed. A kinematic analysis of master and slave manipulators was conducted, based on screw theory and vector loop equation. The relationships of the tendon-driven multi-DOF surgical instrument among Cartesian space, actuator space and joint space were derived for control purposes. The control system architecture of the MicroHand A was designed with intuitive motion control and motion scaling control. Llewellyn's absolute stability criterion and the transparency of the one-DOF master-slave system are also analysed.

Results: Intuitive motion control under dissimilar kinematics in master-slave manipulations and motion scaling control were accomplished to solve absonant hand-eye coordination, kinematic dissimilarity and workspace mismatch of master-slave manipulator problems. A series of tests and animal experiments were carried out to evaluate system performance. The experimental results demonstrate that the system could accomplish intuitive motion control and motion scaling control, and that the control system is stable and reliable.

Conclusions: The experiments performed on the MicroHand A robotic system yielded expected control results. The system satisfies the requirements of minimally invasive surgery. Intuitive motion control and motion scaling control under different kinematics for the master and slave have been implemented.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcs.403DOI Listing

Publication Analysis

Top Keywords

minimally invasive
16
invasive surgery
16
intuitive motion
16
motion control
16
motion scaling
16
scaling control
16
control
14
robot system
12
control system
12
control motion
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!