Objectives: Minimized cardiopulmonary bypass (MCPB) circuits have been shown to reduce cerebral and retinal microembolisation during coronary artery bypass graft (CABG) surgery compared to conventional CPB (CCPB) circuits. Our aim was to evaluate whether the reduction of microembolisation is sustained in aortic valve surgery, as well as to evaluate the effects of MCPB on inflammatory, endothelial, and platelet activation markers.
Material And Methods: Patients were randomized to undergo aortic valve replacement (AVR), with or without CABG, with MPCB (n=20) or CCPB (n=20). After anaesthesia induction and termination of CPB, standardized digital retinal fluorescein angiography images were obtained on both eyes and analyzed in a blinded fashion. Blood samples were collected at eight time points until the third postoperative day.
Results: Fewer patients in the MCPB group showed evidence of microembolic perfusion defects on postperfusion retinal fluorescein angiographs compared to the CCPB group (37% vs. 63%, absolute difference 26%, 95% CI -5% -51%, P = 0.194). Polymorphonuclear leukocyte (PMN) elastase and von Willebrand factor release were statistically significantly reduced in the MCPB group, but there were no significant differences in other markers of inflammation, coagulation or endothelial activation. A significantly higher three-fold increase in the amount of shed blood was collected to the cell saver with a higher rate of intraoperative platelet transfusion in the MCPB group compared to CCPB.
Conclusions: The use of MCPB was associated statistically insignificantly with less retinal microemboli compared to CCPB. MCPB was complicated by excess bleeding and need for transfusion. The feasibility of MCPB techniques in valve surgery requires further studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0267659111415564 | DOI Listing |
Int J Cardiovasc Imaging
January 2025
Cardiology Division, Montefiore Medical Center, Albert Einstein College of Medicine, 111 E 210st, Bronx, NY, USA.
Computed tomography (CT)-derived Epicardial Adipose Tissue (EAT) is linked to cardiovascular disease outcomes. However, its role in patients undergoing Transcatheter Aortic Valve Replacement (TAVR) and the interplay with aortic stenosis (AS) cardiac damage (CD) remains unexplored. We aim to investigate the relationship between EAT characteristics, AS CD, and all-cause mortality.
View Article and Find Full Text PDFHeart Lung Circ
January 2025
Edwards Lifesciences ANZ, Sydney, NSW, Australia.
Background: Untreated severe heart valve disease (HVD) is associated with premature mortality. Research shows low population awareness of when to seek assessment and low focus on cardiac auscultation by physicians in primary care settings. We studied contemporary public knowledge of HVD and assessment by their general practitioner (GP) in Australia.
View Article and Find Full Text PDFCan J Cardiol
January 2025
Division of Cardiac Surgery, Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, MB. Electronic address:
The volume of transcatheter aortic valve implantation (TAVI) for treatment of isolated aortic stenosis has far surpassed surgical aortic valve replacement (SAVR). There has been a consequent increase in TAVI explantation, now the fastest growing cardiac surgical procedure. Transcatheter heart valve explantation can be technically complex, with higher perioperative morbidity and mortality than routine SAVR or valve-in-valve TAVI.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
January 2025
Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine.
Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.
Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.
J Thorac Cardiovasc Surg
January 2025
University of Maryland School of Medicine, Division of Cardiothoracic Surgery. Electronic address:
Objective: Over 30% of patients presenting with acute type A aortic dissection (ATAAD) are considered high - risk or inoperable. This study aims to investigate the early and mid-term outcomes of complex endovascular aortic repair of aortic root, ascending aorta, and aortic arch among patients with ATAAD.
Methods: From January 2018 to January 2023, 29 patients who were considered high risk for open operation underwent endovascular aortic repair.