A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Near-infrared autofluorescence for the detection of parathyroid glands. | LitMetric

Near-infrared autofluorescence for the detection of parathyroid glands.

J Biomed Opt

Vanderbilt University, Department of Biomedical Engineering, VU Station B Box 351631, Nashville, Tennessee 37235, USA.

Published: June 2011

A major challenge in endocrine surgery is the intraoperative detection of parathyroid glands during both thyroidectomies and parathyroidectomies. Current localization techniques such as ultrasound and sestamibi scan are mostly preoperative and rely on an abnormal parathyroid for its detection. In this paper, we present near-infrared (NIR) autofluorescence as a nonintrusive, real-time, automated in vivo method for the detection of the parathyroid gland. A pilot in vivo study was conducted to assess the ability of NIR fluorescence to identify parathyroid glands during thyroid and parathyroidectomies. Fluorescence measurements at 785 nm excitation were obtained intra-operatively from the different tissues exposed in the neck region in 21 patients undergoing endocrine surgery. The fluorescence intensity of the parathyroid gland was found to be consistently greater than that of the thyroid and all other tissues in the neck of all patients. In particular, parathyroid fluorescence was two to eleven times higher than that of the thyroid tissues with peak fluorescence occurring at 820 to 830 nm. These results indicate that NIR fluorescence has the potential to be an excellent optical tool to locate parathyroid tissue during surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1117/1.3583571DOI Listing

Publication Analysis

Top Keywords

detection parathyroid
12
parathyroid glands
12
parathyroid
8
endocrine surgery
8
parathyroid gland
8
nir fluorescence
8
thyroid tissues
8
fluorescence
6
near-infrared autofluorescence
4
detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!