Purpose: High-frequency oscillatory ventilation (HFOV) is usually considered not indicated for treatment of patients with chronic obstructive pulmonary disease (COPD) because of the theoretical risk of air trapping and hyperinflation. The aim of our study was to establish whether HFOV can be safely applied in patients with acute exacerbation of COPD and hypercapnic respiratory failure.
Methods: Ten patients (age, 63-83 years) requiring intensive care treatment who failed on noninvasive ventilation were studied. After initial conventional mechanical ventilation (CMV) of less than 72 hours, all patients were transferred to HFOV for 24 hours and then back to CMV. Arterial blood gases, spirometry, and hemodynamic parameters were repeatedly obtained in all phases of CMV and HFOV at different settings. Regional lung aeration and ventilation were assessed by electrical impedance tomography.
Results: High-frequency oscillatory ventilation was tolerated well; no adverse effects or severe hyperinflation and hemodynamic compromise were observed. Effective CO(2) elimination and oxygenation were achieved. Ventilation was more homogeneously distributed during HFOV than during initial CMV. Higher respiratory system compliance and tidal volume were found during CMV after 24 hours of HFOV.
Conclusions: Our study indicates that short-term HFOV, using lower mean airway pressures than recommended for acute respiratory distress syndrome, appears safe in patients with COPD while securing adequate pulmonary gas exchange.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcrc.2011.04.008 | DOI Listing |
Development
January 2025
Department of Biology, Faculty of Science, Toho University, 2-2-1 Miyama, Funabashi, Chiba, 274-8510, Japan.
Oscillatory dynamics and their modulation are crucial for cellular decision-making; however, analysing these dynamics remains challenging. Here, we present a tool that combines the light-activated adenylate cyclase mPAC with the cAMP biosensor Pink Flamindo, enabling precise manipulation and real-time monitoring of cAMP oscillation frequencies in Dictyostelium. High-frequency modulation of cAMP oscillations induced cell aggregation and multicellular formation, even at low cell densities, such as a few dozen cells.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
National Medical Research Center for Obstetrics, Gynecology and Perinatology Named After Academician Kulakov V.I., 117997 Moscow, Russia.
Despite the increasing number of placenta accreta spectrum (PAS) cases in recent years, its impact on neonatal outcomes and respiratory morbidity, as well as the underlying pathogenetic mechanism, has not yet been extensively studied. Moreover, no study has yet demonstrated the effectiveness of antenatal corticosteroid therapy (CT) for the prevention of respiratory distress syndrome (RDS) in newborns of mothers with PAS at the molecular level. In this regard, microRNA (miRNA) profiling by small RNA deep sequencing and quantitative real-time PCR was performed on 160 blood plasma samples from preterm infants (gestational age: 33-36 weeks) and their mothers who had been diagnosed with or without PAS depending on the timing of the antenatal RDS prophylaxis.
View Article and Find Full Text PDFAndes Pediatr
August 2024
Facultad de Salud, Universidad Santiago de Cali, Cali, Colombia.
Unlabelled: High-frequency oscillatory ventilation with volume guarantee (HFOV-VG) is a ventilatory mode that controls small tidal volumes at supraphysiological frequencies, potentially beneficial for preterm infants with respiratory distress syndrome (RDS).
Objective: To identify the physiological and clinical effects of HFOV-VG in preterm newborns with RDS, compared with conventional HFOV.
Method: Exploratory review of studies published between 2019 and 2023 of preterm newborns from 23 to 36 weeks of gestation with RDS, weighing ≥ 450g, with invasive HFOV support, using PRISMA flow diagram.
Sci Rep
January 2025
School of Electrical Engineering, Southeast University, Nanjing, 210096, China.
In renewable power systems, the interaction between generators, power electronic devices, and the grid has led to frequent high-frequency oscillation (HFO) events. These events can result in significant generation losses and pose serious threats to system stability. Therefore, the rapid and accurate HFO parameter estimation is crucial for early warning and effective mitigation of HFO.
View Article and Find Full Text PDFRespir Res
December 2024
Department of Mechanical and Product Design Engineering, Swinburne University of Technology, Hawthorn, VIC, Australia.
By virtue of applying small tidal volumes, high-frequency ventilation is advocated as a method of minimizing ventilator-induced lung injury. Lung protective benefits are established in infants, but not in other patient cohorts. Efforts to improve and extend the lung protection potential should consider how fundamental modes of gas transport can be exploited to minimize harmful tidal volumes while maintaining or improving ventilation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!