The crater depth value of sample surface during sputtering is important analysis information for the depth profile analysis of glow discharge spectrometry. Real-time sputtered depth measurement with Laser triangulation measurement method for glow discharge compositional analysis, effectively solves the issues of incorrect depth value calculation and complicated procedures in traditional depth analysis method. This paper presents a new Grimm-type glow discharge source for real-time sputtering depth measurement by laser displacement sensor. This GD source also ensures fine sputtering effects and ideal resolution for multi-layer structure and interface. Optical fiber is used to transmit glow spectrum signal from GD-source to multi-channel photoelectric detection system. The design for the first time accomplishes the real-time signal collection and time-based synchronization analysis for both spectrum signal and sputtering depth signal. The real-time sputtering depth measurement curve of standard samples is obtained. The design and operating principle of this new-type GD-source is described in detail. Under the sputtering conditions of 30 mA, 900 V and 20 minutes, the sputtering rates of iron-based and copper-based sample sputtered by this GD source with good depth resolution are about 10 and 55 nm x s(-1). Surface topography picture of sputtering crater and microphotograph of metal samples are provided in the paper. Low-alloy steel standard sample is tested with this new GD source, the relative standard deviation (RSD) of C, Cu, Al, Ni, Mo, Mn and V elements are less than 1.7%, while for Cr and Si elements RSDs are less than 2.6%. The result data of the testing is provided in this paper.
Download full-text PDF |
Source |
---|
Adv Mater
January 2025
Key Laboratory of Green Chemistry & Technology of Ministry of Education, College of Chemistry, Sichuan University, Chengdu, 610064, China.
Inserting metal ions into the porphyrin ring is one of the primary strategies to enhance the properties of porphyrin-based metal-organic frameworks (MOFs). However, the straightforward, rapid, and energy-efficient synthesis of porphyrin-based MOFs with high metallization for the porphyrin ring remains challenging. Herein, a solution anode glow discharge (SAGD) microplasma is presented for the one-step synthesis of scandium-metalloporphyrin frameworks (ScMPFs).
View Article and Find Full Text PDFCold atmospheric pressure plasma (CAPP) comprises an ensemble of ionized gas, neutral particles, and/or reactive species. Electricity is frequently used to produce CAPP via a variety of techniques, including plasma jets, corona discharges, dielectric barrier discharges, and glow discharges. The type and flow rates of the carrier gas(es), temperature, pressure, and vacuum can all be altered to control the desired properties of the CAPP.
View Article and Find Full Text PDFNanoscale Adv
December 2024
Department of Chemistry and Biochemistry, University of Arkansas Fayetteville AR 72701 USA
The use of metal oxide catalysts to enhance plasma CO reduction has seen significant recent development towards processes to reduce greenhouse gas emissions and produce renewable chemical feedstocks. While plasma reactors are effective at producing the intended chemical transformations, the conditions can result in catalyst degradation. Atomic layer deposition (ALD) can be used to synthesize complex, hierarchically structured metal oxide plasma catalysts that, while active for plasma CO reduction, are potentially vulnerable to degradation due to their high surface area and nanoscopic thickness.
View Article and Find Full Text PDFAnal Chem
December 2024
Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084, China.
Molten salt electrolysis has been widely used in the production and separation of metals, but it still lacks in situ real-time analysis methods to monitor the electrolysis process. In this work, a microplasma spectroscopic real-time analysis (MIPECA) system is developed based on noncontact direct current (DC) glow discharge. With the MIPECA system, the atomic emission spectroscopy of Li and K could be obtained in situ in LiCl-KCl molten salt, and the impact of different operating conditions on spectral signals was investigated.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Centre de Recherche et de Restauration des Musées de France (C2RMF), 75008 Paris, France.
Heavy metal pollution, particularly from cadmium (Cd) and copper (Cu), poses significant environmental and health risks. To address the need for efficient, portable, and sensitive detection methods, this study introduces an improved atmospheric pressure glow discharge atomic emission spectrometry (APGD-AES) technique for quantifying Cd and Cu in water samples. The APGD-AES method offers key advantages, including low energy consumption (<33 W), high excitation energy, and compact design.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!