Background: Considerable controversy exists regarding the choice of balloon used for performing angioplasty as treatment of cerebral vasospasm associated with subarachnoid hemorrhage.

Objective: To determine the impact of compliant and noncompliant balloons on angiographic and clinical outcomes among patients with subarachnoid hemorrhage-related cerebral vasospasm.

Methods: Consecutive patients with cerebral vasospasm who underwent balloon angioplasty were included. Patient characteristics, rate of angiographic recurrence, and occurrence of cerebral infarcts in the affected vessel distribution were compared between arteries treated using different balloons.

Results: A total of 30 patients underwent a first-time angioplasty using compliant (n = 34) or noncompliant (n = 51) balloons. At admission, patients were classified Hunt and Hess grade I to III (n = 20) and Hunt and Hess grade IV to V (n = 10). Fisher grades in patients were I (n = 1), II (n = 3), III (n = 20), and IV (n = 6). No significant differences in the rate of angiographic recurrence (32% vs 53%; P = .14), need for repeat angioplasty (21% vs 20%; P = .97), and occurrence of cerebral infarcts in the affected arterial distribution (21% vs 10% P = .39) were observed with compliant and noncompliant balloons, respectively. Independent of the balloon type, a significant reduction in the need for repeat angioplasty was observed when the initial angioplasty resulted in a normal or supranormal diameter compared with a subnormal diameter (63.5% vs 36.5%; P = .01).

Conclusion: No clear difference was observed between compliant and noncompliant balloons for therapeutic angioplasty in preventing angiographic recurrence or the need for repeat angioplasty in patients with subarachnoid hemorrhage-related cerebral vasospasm. An immediate normal or supranormal vessel diameter after the first-time angioplasty resulted in a significant reduction in the need for repeat angioplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1227/NEU.0b013e31822a8976DOI Listing

Publication Analysis

Top Keywords

compliant noncompliant
20
noncompliant balloons
20
cerebral vasospasm
16
repeat angioplasty
16
angiographic recurrence
12
angioplasty
10
angioplasty compliant
8
treatment cerebral
8
vasospasm associated
8
associated subarachnoid
8

Similar Publications

Long-term efficacy of Mirabegron-anticholinergic combination in paediatric neurogenic bladder.

J Pediatr Urol

January 2025

Department of Women and Children's Health, School of Life Course Sciences, Kings College London, London, UK; Children's Bladder Service, Evelina London Children's Hospital, Westminster Bridge Road, London, SE1 7EH, UK.

Introduction: The Mirabegron-anticholinergic (MAC) combination has proven effective as a step-up strategy in managing paediatric neurogenic bladder following anticholinergic medication and botulinum toxin (BTX) therapy. This study assesses the long-term efficacy of MAC in children with neurogenic bladder.

Patients And Methods: A retrospective chart review was conducted from 2015 to 2023, including consecutive paediatric patients receiving Mirabegron (25/50 mg) with an anticholinergic agent (solifenacin 16, tolterodine 7, oxybutynin 7, trospium 1).

View Article and Find Full Text PDF

Background: Non-invasiveness and comfort are crucial in the conservative management of distal radius and scaphoid fractures. While fiberglass casts are standard, three-dimensional (3D)-printed orthoses offer a promising alternative.

Purpose: To compare patient experiences, safety perceptions, and satisfaction between a 3D orthosis and fiberglass cast for distal radius or scaphoid fractures.

View Article and Find Full Text PDF

Serine-modified silver nanoparticle porous spray membrane: A novel approach to wound infection prevention and inflammation reduction.

Int J Pharm

January 2025

College of Pharmaceutical Sciences, Zhejiang University, 866 Yuhangtang Road, Hangzhou, Zhejiang 310058, PR China. Electronic address:

Traditional wound care preparations frequently face challenges such as complex care protocols, poor patient compliance, limited skin permeability, lack of aesthetics, and inconvenience, in addition to the risk of bacterial infection. We developed a spray film preparation containing nanocellulose and L-serine modified nanosilver, capable of rapidly forming a transparent film on the skin within minutes of application. The incorporation of nanocellulose imparted protective, moisturizing, and breathable properties to the film, allowing for easy removal after use.

View Article and Find Full Text PDF

Tuberculosis (TB) is the second deadliest infectious disease worldwide. Current TB diagnostics utilize sputum samples, which are difficult to obtain, and sample processing is time-consuming and difficult. This study developed an integrated diagnostic platform for the rapid visual detection of Mycobacterium tuberculosis (Mtb) in breath samples at the point-of-care (POC), especially in resource-limited settings.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!