Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Failure of coronary sinus lead implantation for resynchronization therapy requires alternative approaches. For such events we have developed a transapical implantation technique as a feasible alternative. We report the outcome of this technique and its evolution from a minithoracotomy to a percutaneous approach. Twenty patients underwent alternative resynchronization therapy with transapical endocardial left ventricular (LV) pacing lead implantation in a multicentre, international study between October 2007 and March 2010. Eighteen patients underwent minithoracotomy and transapical puncture under direct observation. Two recent patients had transthoracic echocardiography-guided percutaneous apical puncture to enter the LV cavity. A 19 or 21 ga needle and two-stage Seldinger dilatation with 4 and 7 Fr sheaths were then used to introduce the lead. In the two patients with closed-chest insertion of the electrode there was no puncture related bleeding or lung damage. Lead dislocation occurred in two minithoracotomy patients. Repositioning was performed without re-opening the pleural cavity. One patient developed right-sided implanted cardiac defibrillator lead endocarditis requiring complete system removal. Twelve patients have >1 year follow-up; all have sustained and significant improvement in LV dimensions (diastolic Δ4.2 ± 2.9, systolic Δ7.2 ± 5.8 mm), ejection fraction (Δ9.5 ± 9.6%), and functional status (Δ1.1 ± 0.3). Transapical placement of LV endocardial pacing lead is an effective alternative strategy for cardiac resynchronization. A closed-chest, percutaneous approach is feasible and should offer even less invasive intervention.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/eur190 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!