A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of Plusoptix S04 in children and teens. | LitMetric

Accuracy of Plusoptix S04 in children and teens.

Can J Ophthalmol

Department of Ophthalmology, Ege University Faculty of Medicine, İzmir, Turkey.

Published: April 2011

Objective: To compare refraction measurements of young patients obtained using Plusoptix S04 with those obtained using cycloplegic retinoscopy.

Design: Cohort study.

Participants: Data were collected from 64 patients (128 eyes), aged 2-19 years.

Methods: All eyes underwent photorefraction using Plusoptix S04 with or without cycloplegia and cycloplegic retinoscopy. Eyes with a maximum spherical and cylinder range of 7.00 to +5.00 were excluded from the study.

Results: The difference in spherical equivalents between Plusoptix S04 without cycloplegia and cycloplegic retinoscopy was more than ±0.50 D in 70.2% of the eyes. In 100 eyes (78.1%), photorefraction underestimated the hyperopic refractive error. The cylinder powers determined by Plusoptix S04 and cycloplegic retinoscopy were similar. The difference in the spherical equivalents between Plusoptix S04 with cycloplegia and cycloplegic retinoscopy was ±0.50 D in 89.8% of the eyes. In 96 eyes (75%), photorefraction with cycloplegia overestimated the hyperopic refractive error. The difference in cylindrical power determined using Plusoptix S04 with cycloplegia and cycloplegic retinoscopy was statistically significant (paired t test, p <0.009).

Conclusions: The statistically significant difference in spherical equivalent values obtained using Plusoptix S04 with or without cycloplegia and cycloplegic retinoscopy suggests that Plusoptix S04 is more in evaluating the cylinder power and axis in young patients. Our results also suggest that Plusoptix S04 is not an accurate tool to estimate the refraction in children.

Download full-text PDF

Source
http://dx.doi.org/10.3129/i10-110DOI Listing

Publication Analysis

Top Keywords

plusoptix s04
28
cycloplegic retinoscopy
20
s04 cycloplegia
16
cycloplegia cycloplegic
16
s04 cycloplegic
8
difference spherical
8
spherical equivalents
8
equivalents plusoptix
8
retinoscopy ±050
8
hyperopic refractive
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!