The phthalates DEHP (Diethylhexyl phthalate), DiNP (Diisononyl phthalate) and DiDP (Diisodecyl phthalate) are constituents of plastisols. We sought to obtain first data on occupational exposures to the above phthalates by analyzing their metabolites in pre- and post-shift urine samples from 5 workers in a car manufacturing plant engaged in seam sealing with a DINP based plastisol. Pre-shift samples were collected after a work-free period of at least 2 days. As a comparison group we investigated 10 employees from the same plant. The comparison group had phthalate exposures in the range of the general German population. All plastisol workers had post shift values of DiNP and DiDP metabolites that were approx. 20-times higher, and pre-shift values that were approx. 5-10 times higher than those of the general background exposure. Post-shift values of DiNP metabolites were (median [maximum]: OH-MiNP: 117 [442] μg/L; oxo-MiNP: 44.3 [175] μg/L; carboxy-MiNP: 57.8 [286]μg/L), pre shift values were (OH-MiNP: 26 [164] μg/L; oxo-MiNP 12.9 [68.6] μg/L; carboxy-MiNP: 32.3 [103] μg/L), compared to the comparison group (OH-MiNP: 6.2 [33]μg/L; oxo-MiNP: 2.8 [16] μg/L; carboxy-MiNP: 6.5 [31] μg/L). DiDP values were generally lower. Regarding DEHP we found no significant work related exposure. The dermal exposure route might play an important role for phthalates in plastisols, with possible influences on distribution and elimination kinetics and therefore data interpretation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.toxlet.2011.06.010 | DOI Listing |
Spine (Phila Pa 1976)
January 2025
Indiana Spine Group Location of investigation Indiana Spine Group, 13225 N. Meridian Street, Carmel, IN 46032.
Study Design: Retrospective cohort.
Objective: To compare the clinical outcomes of trial versus standard clinical practice (SCP) patients following cervical disc arthroplasty (CDA).
Background: CDA is hypothesized to reduce the shear strain and related complications resulting from fusion procedures.
Clin Exp Optom
January 2025
Department of Ophthalmology, Dünyagöz Tunus Hospital, Ankara, Türkiye.
Clinical Relevance: Pseudoexfoliation syndrome (PXS) is a common age-related disorder associated with glaucoma and cataract. Despite its clinical importance, the pathogenesis of PXS is not yet fully understood.
Background: To evaluate levels of SCUBE-1 (signal peptide, CUB domain, and epidermal growth factor-like domain containing protein 1) in the serum and aqueous humour of patients with PXS in comparison with non-PXS controls.
Heliyon
January 2025
Transmission Electronic Microscopy Laboratory, Electronic Microscopy Unit, Department of Biology, University of Cauca, Popayán, 190002, Colombia.
A green methodology for the synthesis of carbon quantum dots (CQDs) from coffee husk without the use of any toxic solvents is proposed in this work. Sonochemical exfoliation of biochar, obtained from the thermal carbonization of coffee husk (from a certified coffee seeds) at low temperature in an air-restricted atmosphere, is described as an alternative procedure for the sustainable production of CQDs. The synthesized CQDs exhibited blue fluorescence with a strong maximum emission band at 410 nm when excited at a maximum absorption wavelength of 330 nm.
View Article and Find Full Text PDFJ Multidiscip Healthc
January 2025
USN Research Group for Older People's Health, University of South-Eastern Norway, Drammen, Norway.
Introduction: Aging is associated with the potential onset of vision and hearing problems, affecting the quality of life and functional independence of older adults. This study sought to investigate the prevalence of various vision and hearing problems in 76-year-old Faroese individuals and examine possible regional variations in these health issues.
Materials And Methods: A cross-sectional study design was used, surveying 175 participants, all 76-year-olds, from different regions in the Faroe Islands.
J Dent Sci
December 2024
Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Chulalongkorn University, Bangkok, Thailand.
Background/purpose: Many designs of static computer-assisted implant surgery (sCAIS) are available for clinician to achieve proper implant position. However, there were not any studies that approached the design alone to evaluate whether sleeve-in-sleeve or sleeve-on-drill design provided most accuracy implant position. The purpose of this study was to investigate the precision of implant placement with sleeve-in-sleeve and sleeve-on-drill static computer assisted implant surgery (sCAIS) designs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!