Purpose: To evaluate the shear bond strength (SBS) of a novel low-shrink posterior resin composite (Filtek LS) to various substrates.

Methods: The dedicated LS System Adhesive was used to bond Filtek LS to bovine dentin, ground bovine enamel, resin-modified glass-ionomer liner (Vitrebond Plus), conventional glass-ionomer restorative material (Fuji IX GP Extra), and bovine dentin previously exposed to zinc oxide-eugenol (IRM) (n=10 for each group). Vitrebond Plus and Fuji IX GP Extra substrates were fabricated by filling standardized preparations that had been made in epoxy resin. Adper Scotchbond SE/Filtek Z250 was used as a control. Composites were applied using the Ultradent specimen former. The bonded specimens were stored in water at 37 degrees C for 24 hours, and SBS testing was done using an Instron universal testing machine. The data were analyzed using ANOVA and Tukey-Kramer HSD test at a significance level of 0.05.

Results: The mean SBS values of the Filtek LS system were generally somewhat lower than the values of Adper Scotchbond SE/Filtek Z250 to the various substrates, but the differences were not statistically significant. Exposure of dentin to IRM resulted in a statistically significant reduction in the mean SBS values of Adper Scotchbond SE/Z250 and a slight but statistically insignificant reduction for the Filtek LS system.

Download full-text PDF

Source

Publication Analysis

Top Keywords

adper scotchbond
12
bovine dentin
8
fuji extra
8
scotchbond se/filtek
8
se/filtek z250
8
sbs values
8
filtek system
8
values adper
8
bond strengths
4
strengths silorane
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!