We report the results of the Birmingham Mid-Head Resection Arthroplasty (BMHR) for patients with poor femoral head bone quality where standard hip resurfacing is contraindicated. This is a clinical and radiological follow-up of the first 35 consecutive procedures (34 patients, 16 male, 18 female) performed by an independent surgeon. The mean follow-up was 2.8 years (2.1 to 4.1) and no patients were lost to follow-up. The mean age at the time of surgery was 50.4 years (23.8 to 69.4). There were no failures. The mean HHS improved from 46.6 (25 to 70) pre-operatively to 96.1 (72 to 100) post-operatively. The mean OHS was 36.4 (19 to 53) pre-operatively and 14.2 (12 to 34) post-operatively. The mean WOMAC score was 45.6 (7 to 92) pre-operatively and 4.3 (0 to 28) post-operatively. The mean UCLA activity score was 4.5 (1 to 9) pre-operatively and 7.6 (5 to 10) post-operatively. Radiographic analysis did not show any adverse features such as stress shielding, loosening or femoral neck narrowing. The BMHR provides an excellent alternative to conventional total hip arthroplasty in patients with poor femoral head bone quality who are not suitable for standard resurfacing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5301/HIP.2011.8407 | DOI Listing |
Int J Surg Case Rep
October 2019
Complejo Asistencial Universitario de Salamanca, Paseo de San Vicente 58-182, 37001, Spain. Electronic address:
Introduction: Total hip arthroplasty in young patients can cause problems when it comes to choosing a suitable implant. The Birmingham Mid-Head Resection prosthesis (BMHR) offers the option of preserving bone stock despite its poor quality in the femoral neck. Femoral neck fractures are a known complication of hip resurfacing prostheses and the main reason for revision surgery.
View Article and Find Full Text PDFHip Int
January 2021
Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK.
Background: Blood metal ion levels are used in the surveillance of metal-on-metal (MoM) hip implants. Modular implants contain an extra source of metal debris that may affect the ratio of metal ions in the blood.
Methods: This was a retrospective study of 503 patients with hip replacements made by a single manufacturer (Smith & Nephew, Warwick, UK) with the same bearing surface.
Clin Orthop Surg
September 2015
Department of Orthopaedics, Charing Cross Hospital, Imperial College London, London, UK.
Total hip arthroplasty in the young leads to difficult choices in implant selection. Until recently bone conserving options were not available for younger patients with deficient femoral head bone stock. The novel Birmingham Mid-Head Resection (BMHR) device offers the option of bone conserving arthroplasty in spite of deficient femoral head bone stock.
View Article and Find Full Text PDFClin Orthop Relat Res
December 2015
The London Hip Unit, 30 Devonshire Street, London, W1G 6PU, UK.
Clin Orthop Relat Res
December 2015
Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 W. Belvedere Ave., Baltimore, MD, 21215, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!