We report the results of the Birmingham Mid-Head Resection Arthroplasty (BMHR) for patients with poor femoral head bone quality where standard hip resurfacing is contraindicated. This is a clinical and radiological follow-up of the first 35 consecutive procedures (34 patients, 16 male, 18 female) performed by an independent surgeon. The mean follow-up was 2.8 years (2.1 to 4.1) and no patients were lost to follow-up. The mean age at the time of surgery was 50.4 years (23.8 to 69.4). There were no failures. The mean HHS improved from 46.6 (25 to 70) pre-operatively to 96.1 (72 to 100) post-operatively. The mean OHS was 36.4 (19 to 53) pre-operatively and 14.2 (12 to 34) post-operatively. The mean WOMAC score was 45.6 (7 to 92) pre-operatively and 4.3 (0 to 28) post-operatively. The mean UCLA activity score was 4.5 (1 to 9) pre-operatively and 7.6 (5 to 10) post-operatively. Radiographic analysis did not show any adverse features such as stress shielding, loosening or femoral neck narrowing. The BMHR provides an excellent alternative to conventional total hip arthroplasty in patients with poor femoral head bone quality who are not suitable for standard resurfacing.

Download full-text PDF

Source
http://dx.doi.org/10.5301/HIP.2011.8407DOI Listing

Publication Analysis

Top Keywords

birmingham mid-head
8
mid-head resection
8
clinical radiological
8
radiological follow-up
8
patients poor
8
poor femoral
8
femoral head
8
head bone
8
bone quality
8
pre-operatively post-operatively
8

Similar Publications

Introduction: Total hip arthroplasty in young patients can cause problems when it comes to choosing a suitable implant. The Birmingham Mid-Head Resection prosthesis (BMHR) offers the option of preserving bone stock despite its poor quality in the femoral neck. Femoral neck fractures are a known complication of hip resurfacing prostheses and the main reason for revision surgery.

View Article and Find Full Text PDF

Does modularity of metal-on-metal hip implants increase cobalt: chromium ratio?

Hip Int

January 2021

Institute of Orthopaedics and Musculoskeletal Science (University College London), Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK.

Background: Blood metal ion levels are used in the surveillance of metal-on-metal (MoM) hip implants. Modular implants contain an extra source of metal debris that may affect the ratio of metal ions in the blood.

Methods: This was a retrospective study of 503 patients with hip replacements made by a single manufacturer (Smith & Nephew, Warwick, UK) with the same bearing surface.

View Article and Find Full Text PDF

Birmingham Mid-Head Resection Periprosthetic Fracture.

Clin Orthop Surg

September 2015

Department of Orthopaedics, Charing Cross Hospital, Imperial College London, London, UK.

Total hip arthroplasty in the young leads to difficult choices in implant selection. Until recently bone conserving options were not available for younger patients with deficient femoral head bone stock. The novel Birmingham Mid-Head Resection (BMHR) device offers the option of bone conserving arthroplasty in spite of deficient femoral head bone stock.

View Article and Find Full Text PDF

CORR Insights(®): frequent femoral neck osteolysis with Birmingham mid-head resection resurfacing arthroplasty in young patients.

Clin Orthop Relat Res

December 2015

Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 W. Belvedere Ave., Baltimore, MD, 21215, USA.

View Article and Find Full Text PDF