A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental and computational analysis of soft tissue stiffness in forearm using a manual indentation device. | LitMetric

A hand held stiffness meter can be used to measure indentation stiffness of human soft tissues, sensitively altered, e.g., by pathological tissue swelling. Under indentation load, the relative contribution of each soft tissue component (i.e., skin, adipose tissue and muscle) to the biomechanical response is not known. In the present study, we evaluated the biomechanical role of different soft tissues in relaxed, physically stressed and oedemic human forearm. Soft tissue stiffness of the forearms of nine healthy human subjects was measured under four different test protocols: (1) forearm at rest, (2) forearm under isometric flexor loading, (3) forearm under isometric extensor loading, and (4) forearm under venous occlusion. In (2) and (3) the loading forces were monitored using a dynamometer, and in (4) the soft tissue swelling was induced by venous occlusion using a pressure cuff. At the site of indentation, thickness of different tissue layers (skin, adipose tissue and muscle) was measured using B-mode ultrasound imaging. Layered, hyperelastic finite element (FE) model of the indentation measurement was created and the model response was matched with that of the stiffness meter to determine the elastic modulus for each tissue in the model. Optimized values of the elastic modulus for skin and adipose tissue at rest were 210 kPa and 1.9 kPa, respectively. Further, significance of the variations in stiffness of different tissues on the indentation response was tested. Experimentally, indentation stiffness of the forearm increased during isometric extensor and flexor loads as well as under venous occlusion by 53, 91 and 15%, respectively. The FE model could reproduce the experimental responses primarily by the increased modulus of skin; 112% (446 kPa), 210% (651 kPa) and 21% (254 kPa) under flexor and extensor loading as well as during venous occlusion, respectively. The indentation response was 9-16 times more sensitive to changes in the mechanical properties of skin than those of adipose tissue and muscle. In conclusion, the present stiffness meter may be used to quantify in vivo mechanical properties of soft tissues in the forearm, sensitively modulated by soft tissue swelling and muscle loading.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2011.05.015DOI Listing

Publication Analysis

Top Keywords

soft tissue
20
skin adipose
16
adipose tissue
16
venous occlusion
16
tissue
12
stiffness meter
12
soft tissues
12
tissue swelling
12
tissue muscle
12
soft
8