A microfabricated thermal modulator (μTM) designed for ultimate use in a comprehensive two-dimensional microscale gas chromatography (μGC × μGC) system is evaluated. The 2-stage device measures 13 mm (l) × 6 mm (w) × 0.5 mm (h) and consists of two interconnected serpentine etched-Si microchannels suspended from a thin Pyrex cap and wall-coated with PDMS (polydimethylsiloxane). The chip is mounted within a few tens of micrometers of a thermoelectric cooler that maintains both stages at a baseline temperature between -35 and -20 °C in order to focus analytes eluting from an upstream separation column. Each stage is heated to 210 °C sequentially at a rate as high as 2400 °C/s by independent thin-film resistors to inject the analytes in consecutive fractions to a downstream column, and then cooled at a rate as high as -168 °C/s. The average power dissipation is only ∼10 W for heating and 21 W for cooling without using consumable materials. In this study, the outlet of the μTM is connected directly to a flame ionization detector to assess its performance. Following a demonstration of basic operation, the modulated peak amplitude enhancement (PAE) and full-width-at-half-maximum (fwhm) are evaluated for members of a series of n-alkanes (C(6)-C(10)) as a function of the rim and stage temperatures; modulation period, phase, and offset; analyte concentration; and carrier-gas flow rate. A PAE as high as 50 and a fwhm as narrow as 90 ms are achieved for n-octane under optimized conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac200336eDOI Listing

Publication Analysis

Top Keywords

microfabricated thermal
8
thermal modulator
8
comprehensive two-dimensional
8
two-dimensional microscale
8
microscale gas
8
gas chromatography
8
rate high
8
evaluation microfabricated
4
modulator comprehensive
4
chromatography microfabricated
4

Similar Publications

Quantum technology exploits fragile quantum electronic phenomena whose energy scales demand ultra-low electron temperature operation. The lack of electron-phonon coupling at cryogenic temperatures makes cooling the electrons down to a few tens of millikelvin a non-trivial task, requiring extensive efforts on thermalization and filtering high-frequency noise. Existing techniques employ bulky and heavy cryogenic metal-powder filters, which prove ineffective at sub-GHz frequency regimes and unsuitable for high-density quantum circuits such as spin qubits.

View Article and Find Full Text PDF

A set of nCN/WO composites was synthesized through a simple thermal treatment for gold recovery from the simulated effluent of a non-cyanide-based plating bath. The obtained results exhibited that all nCN/WO composites demonstrated a higher photocatalytic activity for gold recovery than their pristine components due to the formation of nanocomposites which paved a convenient pathway for charge transfer. Among all synthesized composites, the 5.

View Article and Find Full Text PDF

The primary method of treatment for patients suffering from drug-resistant focal-onset epilepsy is resective surgery, which adversely impacts neurocognitive function. Radio frequency (RF) ablation and laser ablation are the methods with the most promise, achieving seizure-free rates similar to resection but with less negative impact on neurocognitive function. However, there remains a number of concerns and open technical questions about these two methods of thermal ablation, with the primary ones: (1) heating; (2) hemorrhage and bleeding; and (3) poor directionality.

View Article and Find Full Text PDF

Background: Over the past decade, saliva-based liquid biopsies have emerged as promising tools for the early diagnosis, prognosis, and monitoring of cancer, particularly in high-risk populations. However, challenges persist because of low concentrations and variable modifications of biomarkers linked to tumor development when compared to normal salivary components.

Methods: This study explores the application of differential scanning calorimetry (DSC)-based thermal liquid biopsy (TLB) for analyzing saliva and blood plasma samples from head and neck cancer (HNC) patients.

View Article and Find Full Text PDF

Design and characterization of novel graphene-enhanced vapor chambers for lightweight and high-performance electronics cooling.

Nanotechnology

January 2025

Electronics Materials and Systems Laboratory, Department of Microtechnology and Nanoscience (MC2), Chalmers University of Technology, Kemivägen 9, SE-412 96 Göteborg, Sweden.

The trend towards miniaturization of electronics and increasing transistor density in semiconductors requires more efficient cooling solutions. Vapor chambers are well established passive cooling devices that are used in a wide variety of electronics. Commercial vapor chambers are often made of high-density metals such as copper which can be a downside in lightweight applications such as laptops, smartphones, and tablets.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!