An evalution of compressive strength of newer nanocomposite: An in vitro study.

J Conserv Dent

Department of Conservative Dentistry And Endodontics, A.B. Shetty Memorial Institute Of Dental Sciences, Deralakatte, Mangalore, India.

Published: January 2011

Aim: The purpose of the study is to assess and compare compressive strength of newer nanocomposites (FiltekZ350, Ceram X Mono, Ceram X Duo) with microhybrid (Tetric Ceram) and to compare difference in compressive strength of newer nanocomposites.

Materials And Methods: Forty eight specimens of composite were fabricated using customized biparpite brass mold measuring 5mm x 5mm and were grouped with twelve specimens in each Group I : Tetric Ceram, Group II: Filtek Z 350, Group III : Ceram X Mono, Group IV : Ceram X Duo. Composite resins are placed in cylindrical recesses and covered with mylar strip and are cured using QHL light curing unit. Compressive strength is evaluated using Instron machine. Results are statistically analyzed using One way Anova and Student t test. Analysis demonstrated that nanocomposites have better compressive strength than micro hybrid (P<0.001).

Results: Within the limitations of the study, it can be concluded that nanocomposites have better compressive strength than microhybrid composite and nanocomposite showed optimal compressive strength of 312 - 417 Mpa.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3099111PMC
http://dx.doi.org/10.4103/0972-0707.80734DOI Listing

Publication Analysis

Top Keywords

compressive strength
20
strength newer
12
ceram mono
8
ceram duo
8
tetric ceram
8
ceram
6
strength
5
evalution compressive
4
newer nanocomposite
4
nanocomposite vitro
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!