Low intensity pulsed ultrasound (LIPUS) was proven to enhance fracture healing effectively. Similar effect of LIPUS on accelerating the osteoporotic fracture healing was therefore hypothesized. The normal and osteoporotic fracture healings under this non-invasive biophysical intervention of LIPUS were compared and investigated. Closed femoral fracture procedures were performed on 120 Sprague-Dawley rats, in which 60 of them were ovariectomized (OVX). The rats were randomly assigned into four groups: sham OVX with treatment (Sham-T), sham OVX control (Sham-C), OVX with treatment (OVX-T) and OXV control (OVX-C). LIPUS treatment was 20 min a day, 5 days a week for durations of 2, 4, or 8 weeks. Results from weekly radiography, histomorphometry, micro-computed tomography and mechanical test showed both the treatment groups were with better healing responses than their control groups. Moreover, between the normal and the osteoporotic treatment groups, a significantly higher (p = 0.015) callus width (week 4), higher ratio of increment in bone volume to tissue volume ratio value (7.4% more), faster response of endochondral ossification and a higher stiffness measurement were observed in the osteoporotic treatment group. These comparable results on healing responses imply that LIPUS can be applied clinically to enhance both normal and osteoporotic fracture healing.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jor.21487DOI Listing

Publication Analysis

Top Keywords

fracture healing
16
osteoporotic fracture
12
normal osteoporotic
12
low intensity
8
intensity pulsed
8
pulsed ultrasound
8
sham ovx
8
ovx treatment
8
treatment groups
8
healing responses
8

Similar Publications

Introduction: Proximal humerus fractures are a common orthopedic challenge, particularly in older adults. Percutaneous pinning, a minimally invasive technique, aims to stabilize fractures while preserving soft tissue integrity. This study evaluates the functional and radiological outcomes of patients treated with percutaneous pinning at a single center over five years.

View Article and Find Full Text PDF

Ankle fractures, often accompanied by other injuries and complications, pose a significant healthcare burden due to their high incidence and associated treatment challenges. This case report investigates the use of Cytal™ Wound Matrix, derived from urinary bladder matrix (UBM), in managing postoperative complications following open reduction and internal fixation (ORIF) of a trimalleolar ankle fracture. A 57-year-old male with a history of hypertension sustained a trimalleolar ankle fracture following a road traffic accident.

View Article and Find Full Text PDF

Bioelectronic osteosynthesis plate to monitor the fracture bone healing using electric capacitive variations.

J Orthop Surg Res

January 2025

Department of Mechanical Engineering, Centre for Mechanical Technology & Automation (TEMA), University of Aveiro, Aveiro, 3810-193, Portugal.

Background: Bone fractures represent a global public health issue. Over the past few decades, a sustained increase in the number of incidents and prevalent cases have been reported, as well as in the years lived with disability. Current monitoring techniques predominantly rely on imaging methods, which can result in subjective assessments, and expose patients to unnecessary cumulative doses of radiation.

View Article and Find Full Text PDF

Background: To analyze the effects of the positioning of a bolt in the femoral neck system (FNS) on the short-term outcomes of middle-aged and young adults with displaced femoral neck fractures (FNFs).

Methods: This was a retrospective study involving 114 middle-aged and young adults with displaced FNFs who were surgically treated with internal fixation via the FNS in the Department of Orthopedics, Suzhou Municipal Hospital, from December 2019 to January 2023. The degree of deviation of the central axis of the femoral head and neck from the tip of the bolt (W), the tip‒apex distance (TAD) and the length of femoral neck shortening (LFNS) were measured on postoperative X-ray and computed tomography (CT) scan images.

View Article and Find Full Text PDF

Robot-assisted Endodontic Retreatment: A Case Report with Clinical Considerations.

J Endod

January 2025

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China; Department of Cariology and Endodontics, School and Hospital of Stomatology, Wuhan University, Wuhan, China. Electronic address:

Introduction: Fiber posts present significant challenges for nonsurgical endodontic retreatment, as improper removal may result in iatrogenic root perforation or even root fracture. Recently, robotic technology has attracted considerable attention in dentistry and active dental robotic (ADR) systems can perform procedures based on preset instructions, minimizing reliance on the dentist's experience. This case report describes the application of an ADR system for fiber post removal through an existing zirconia crown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!