AI Article Synopsis

Article Abstract

In this Letter, we report for the first time (to our knowledge) in-vivo volumetric optical coherence microscopy images of skin epidermal cells. We achieved micrometer-class resolution, 2 μm laterally and axially, with an acquisition speed of 23 K A-scans/s and over 90 dB sensitivity to a depth of 1 mm by employing a custom, liquid-lens-based, dynamic-focusing objective, a broadband light source, and a custom, astigmatism-corrected Czerny-Turner spectrometer with a high-speed complementary metal-oxide-semiconductor camera.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.36.002221DOI Listing

Publication Analysis

Top Keywords

optical coherence
8
coherence microscopy
8
acquisition speed
8
cellular resolution
4
resolution optical
4
microscopy high
4
high acquisition
4
speed in-vivo
4
in-vivo human
4
human skin
4

Similar Publications

Purpose: To study choroidal thickness (CT) and luminal areas of choroidal vessels in the setting of fovea-off rhegmatogenous retinal detachment (RRD).

Methods: Twenty-seven eyes with RRD were prospectively studied before and after pars plana vitrectomy and SF6 tamponade, using swept-source optical coherence tomography (SS-OCT). CT was measured pre- and postoperatively both subfoveally and in attached macular areas.

View Article and Find Full Text PDF

Objective: To investigate the effects of bulk-fill, resin-based composite types (high or low viscosity) on the internal adaptation of Class V restorations.

Study Design: Experimental study. Place and Duration of the Study: Hefei Stomatological Hospital, Hefei, China, from October 2022 to December 2023.

View Article and Find Full Text PDF

Background: While vaccination remains crucial in mitigating the impact of the COVID-19 pandemic, several ocular adverse events has been reported, including Acute Zonal Occult Outer Retinopathy (AZOOR) complex.

Case Presentation: A 31-year-old female presented declined best corrected visual acuity (BCVA) and flashes in both eyes three days following second recombinant mRNA COVID-19 vaccine (Moderna). Fundus autofluorescence (FAF) illustrated speckled hyper-AF lesions surrounding right eye torpedo maculopathy site and hyper-AF lesions in the left macula.

View Article and Find Full Text PDF

Background: This study evaluates retinal oxygen saturation and vessel density within the macula and correlates these measures in controls and subjects with type 2 diabetes (DM) with (DMR) and without (DMnR) retinopathy. Changes in retinal oxygen saturation have not been evaluated regionally in diabetic patients.

Methods: Data from seventy subjects (28 controls, 26 DMnR, and 16 DMR were analyzed.

View Article and Find Full Text PDF

Background/ Aims: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (pRNFL) thickness using optical coherence tomography (OCT) after implantation of a PRESERFLO® microshunt for surgical glaucoma management in adult glaucoma patients.

Methods: Retrospective data analysis of 59 eyes of 59 participants undergoing implantation of a PRESERFLO microshunt between 2019 and 2022 at a tertiary center for glaucoma management. Surgical management included primary temporary occlusion of the glaucoma shunt to prevent early hypotony.

View Article and Find Full Text PDF