A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dynamic tracheal occlusion improves lung morphometrics and function in the fetal lamb model of congenital diaphragmatic hernia. | LitMetric

Background: Congenital diaphragmatic hernia (CDH) is associated with significant neonatal morbidity and mortality. Although prenatal complete tracheal occlusion (cTO) causes hypoplastic CDH lungs to enlarge, improved lung function has not been demonstrated. Furthermore, cTO interferes with the dynamic pressure change and fluid flow associated with fetal breathing.

Purpose: The purpose of the study was to assess a novel dynamic tracheal occlusion (dTO) device that preserves pressure changes and fluid flow.

Methods: In this pilot study, CDH was created in fetal lambs at 65 days of gestational age (GA). At 110 days GA, a cTO device (n = 3) or a dTO device (n = 4) was placed in the fetal trachea. At 135 days GA, lambs were delivered and resuscitated. Unoperated lamb co-twins (n = 5), sham thoracotomy lambs (n = 2), and untreated CDH lambs (n = 3) served as controls.

Results: Tracheal opening pressure, lung volume, lung fluid total protein, and phospholipid were significantly higher in the cTO group than in the dTO and unoperated control groups. Maximal oxygenation and lung compliance were significantly lower in the cTO group when compared with the unoperated control and dTO groups.

Conclusion: Preliminary results suggest that in the fetal lamb CDH model, dTO restores normal lung morphometrics and function, whereas cTO leads to enlarged but less functional lungs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3128884PMC
http://dx.doi.org/10.1016/j.jpedsurg.2011.03.049DOI Listing

Publication Analysis

Top Keywords

tracheal occlusion
12
dynamic tracheal
8
lung morphometrics
8
morphometrics function
8
fetal lamb
8
congenital diaphragmatic
8
diaphragmatic hernia
8
dto device
8
cto group
8
unoperated control
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!