Aim: The study aims to provide objective data for the displacement of titanium screw implants in trabecular bone specimens. One hundred Semados implants (Bego, Bremen, Germany) were inserted in bovine type IV bone specimens. All implants had a diameter of 3.75 mm; 50 implants had a length of 8.5 mm and 50 implants had a length of 15 mm. Insertion torque was determined at intervals of 10, 20, and 30 Ncm. Implants were loaded horizontally with 10, 20, and 30 N for 2 seconds. An indicator strip was attached to the implant abutment to allow direct observation of implant movement relative to the bone surface. Horizontal displacement was assessed with an accuracy of measurement of 10 µm. Seven implants got lost by visible loosening. Degree of displacement was subject to evaluation with all others. Those implants showed a mean displacement of 59 µm for 10 N (n = 100), 173 µm for 20 N (n = 99), and 211 µm for 30 N (n = 93). The mean displacement of 15-mm implants (16, 37, 51 µm) was significantly lower compared with 8.5-mm implants (103, 311, 396 µm) corresponding to 10, 20, and 30 N as lateral loads.
Conclusions: Displacement of screw implants in trabecular bone can be detected and visualized using commercially available endoscopes with a high magnification. A lateral load of 20 N indicates a mean displacement of over 100 µm and therefore results in a critical displacement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1708-8208.2011.00338.x | DOI Listing |
JAMA Otolaryngol Head Neck Surg
January 2025
Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
Importance: Cochlear implants enable improvements in speech perception, but music perception outcomes remain variable. Image-guided cochlear implant programming has emerged as a potential programming strategy for increasing the quality of spectral information delivered through the cochlear implant to improve outcomes.
Objectives: To perform 2 experiments, the first of which modeled the variance in music perception scores as a function of electrode positioning factors, and the second of which evaluated image-guided cochlear implant programming as a strategy to improve music perception with a cochlear implant.
Vet Res Commun
January 2025
Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, Zabrze, 41-800, Poland.
Chronic instability at the lumbosacral junction, particularly between the L7 vertebra and the sacral bone, presents significant challenges in veterinary orthopedics, especially for large breed dogs. This condition frequently results in severe pain, neurological deficits, and mobility impairments, prompting the development of various surgical techniques aimed at effectively stabilizing the affected area. A critical evaluation of the literature on surgical stabilization of the lumbosacral spine in dogs reveals the clinical applications, outcomes, and future directions in veterinary spinal surgery.
View Article and Find Full Text PDFStrahlenther Onkol
January 2025
Department of Radiation Oncology, University Hospital Düsseldorf, Düsseldorf, Germany.
Purpose: The aim of this review is to give an overview of the results of prospective and retrospective studies using allogenic reconstruction and postmastectomy radiotherapy (PMRT) in breast cancer and to make recommendations regarding this interdisciplinary approach.
Materials And Methods: A PubMed search was conducted to extract relevant articles from 2000 to 2024. The search was performed using the following terms: (breast cancer) AND (reconstruction OR implant OR expander) AND (radiotherapy OR radiation).
Int Orthop
January 2025
CHU de Nantes, Nantes University, CHU Nantes, Clinique Chirurgicale Orthopédique et Traumatologique, 1 Place Alexis Ricordeau, 44000, Nantes, France.
Purpose: Proximal femur megaprostheses (PFMPs) are used to manage large bone defects in both non-oncological indications (NOI) and oncological indications (OI). However, little is known about the comparative risks of reoperation and functional outcomes between these groups. This study aimed to evaluate the cumulative incidences of reoperation and functional results of PFMPs between NOI and OI.
View Article and Find Full Text PDFJ Assist Reprod Genet
January 2025
APHP Centre, Faculty of Medicine, Université Paris Cité, 75014, Paris, France.
Purpose: To evaluate if morphology and morphokinetics of cleaved embryos affect prenatal and perinatal outcomes.
Methods: This retrospective cohort study included 734 single fresh embryo transfer (SET) from ICSI from January 2014 to December 2020 at the Dijon University Hospital. Using time-lapse technology, embryos were defined as TOP or non-TOP according to morphological/morphokinetic criteria.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!