Conductance catheter measurements of lumen area of stenotic coronary arteries: theory and experiment.

J Appl Physiol (1985)

Dept. of Biomedical Engineering, Indiana Univ. Purdue Univ., Indianapolis, Indianapolis, IN 46202, USA.

Published: September 2011

An injection of saline solution is required for the measurement of vessel lumen area using a conductance catheter. The injection of room temperature saline to displace blood in a vessel inevitably involves mass and heat transport and electric field conductance. The objective of the present study is to understand the accuracy of conductance method based on the phenomena associated with the saline injection into a stenotic blood vessel. Computational fluid dynamics were performed to simulate flow and its relation to transport and electric field in a stenotic artery for two different sized conductance catheters (0.9 and 0.35 mm diameter) over a range of occlusions [56-84% cross-sectional area (CSA) stenosis]. The results suggest that the performance of conductance catheter is dependent on catheter size and severity of stenosis more significantly for 0.9 mm than for 0.35 mm catheter. Specifically, the time of detection of 95% of injected saline solution at the detection electrodes was shown to range from 0.67 to 3.7 s and 0.82 to 0.94 s for 0.9 mm and 0.35 mm catheter, respectively. The results also suggest that the detection electrodes of conductance catheter should be placed outside of flow recirculation region distal to the stenosis to minimize the detection time. Finally, the simulations show that the accuracy in distal CSA measurements, however, is not significantly altered by whether the position of detection electrodes is inside or outside of recirculation zone (error was within 12% regardless of detection electrodes position). The results were experimentally validated for one lesion geometry and the simulation results are within 8% of actual measurements. The simulation of conductance catheter injection method may lead to further optimization of device and method for accurate sizing of diseased coronary arteries, which has clinical relevance to percutaneous intervention.

Download full-text PDF

Source
http://dx.doi.org/10.1152/japplphysiol.00304.2011DOI Listing

Publication Analysis

Top Keywords

conductance catheter
20
detection electrodes
16
conductance
8
lumen area
8
coronary arteries
8
saline solution
8
catheter injection
8
blood vessel
8
transport electric
8
electric field
8

Similar Publications

Background: Intrabdominal pressure (IAP) is an important parameter. Elevated IAP can reduce visceral perfusion, lead to intraabdominal hypertension, and result in life-threatening abdominal compartment syndrome. While ingestible capsular devices have been used for various abdominal diagnoses, their application in continuous IAP monitoring remains unproven.

View Article and Find Full Text PDF

Timely and effective rescue of critically ill children no longer solely relies on advanced medical technology; vascular access plays a pivotal role. Best practice recommendations for nursing in vascular access are critical for ICU patients. However, clear guidelines for the maintenance of external infusion connection devices remain lacking.

View Article and Find Full Text PDF

Atrial fibrillation (AF) is the most common cardiac arrhythmia and pulmonary vein isolation (PVI) by percutaneous transcatheter ablation is its pivotal treatment. Nowadays, several techniques using different energy sources are used, such as radiofrequency (RF), cryoablation and laser ablation. A new technology that combines the strengths of different techniques has been developed, in particular having both the speed of one-shot techniques and the selectivity and precision of point-by-point RF: the RF balloon (RFB).

View Article and Find Full Text PDF

A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation.

J Cardiothorac Surg

January 2025

Department of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular Disease, Fuzhou, 350001, China.

Objective: The objective of this study is to assess the predictive utility of perioperative P-wave parameters in patients with paroxysmal atrial fibrillation (PAF) undergoing catheter ablation, and to develop a predictive model using these parameters.

Methods: A total of 213 patients with PAF undergoing catheter ablation were retrospectively analyzed. P-wave parameters were measured within 3 days preoperatively and on the day postoperatively to determine their predictive significance for postoperative PAF recurrence.

View Article and Find Full Text PDF

The incidence of inflow and drain pain and associated risk factors for patients on peritoneal dialysis.

BMC Nephrol

January 2025

Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, 58th, Zhongshan Road II, Guangzhou, 510080, Guangdong, PR China.

Background: The high prevalence and prolonged duration of inflow pain and drain pain experienced by peritoneal dialysis (PD) patients following PD catheter implantation impact their quality of life. However, there is limited data on the frequency and predisposing factors of these pains in the Chinese population undergoing peritoneal dialysis.

Methods: This study encompassed individuals who underwent peritoneal dialysis catheter implantation at our institution from September 1, 2023, to March 31, 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!