Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The granulocyte-macrophage colony stimulating factor (GM-CSF) is a cytokine that regulates the proliferation and differentiation of hematopoietic cells and activates granulocytes and macrophages. A reversed-phase liquid chromatography (RP-LC) method was validated for the assessing of the stability of non-glycosylated recombinant rhGM-CSF (Molgramostim) in biopharmaceutical formulations. The RP-LC method was carried out on a Jupiter C(4) column (250 mm × 4.6 mm i.d.), maintained at 45 °C. The mobile phase A consisted of 0.1% TFA and the mobile phase B was acetonitrile with 0.1% TFA in acetonitrile, run at a flow rate of 1 mL/min, and using photodiode array (PDA) detection at 214 nm. Chromatographic separation was obtained with a retention time of 29.2 min, and was linear over the concentration range of 2-300 μg/mL (r(2) = 0.9992). Specificity was established in degradation studies. Moreover, the in vitro cytotoxicity test of the degraded products showed significant differences (p < 0.05). The method was applied to the assessment of rhGM-CSF and related proteins in biopharmaceutical dosage forms, and the results were correlated to those of a bioassay. It is concluded that the employment of RP-LC in conjunction with current methods allows a great improvement in monitoring stability, quality control and thereby assures the therapeutic efficacy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.biologicals.2011.05.002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!