Purpose: The purpose of this study was to evaluate the outcomes of ultrasound-guided femoral artery access for total percutaneous endovascular repair of abdominal and thoracic aortic aneurysms.
Materials And Methods: Total percutaneous aneurysm repair of the abdominal and thoracic aorta was performed in 52 consecutive patients (46 males, 6 females; mean age, 64.6±16 years; age range, 24-93 years) in a total of 85 access arteries. Of the aortic aneurysms repaired, 33 were abdominal, and 19 were thoracic. Ultrasound- guided puncture of the access artery was performed in all patients. The access artery was closed with a Prostar XL device at the end of the procedure.
Results: The outer diameter of the vascular sheaths or the stent graft system ranged from 14 F to 27 F. All but one patient achieved successful closure of the arterial puncture with the closure device. One patient required surgical cutdown because of device failure. Two patients required long-duration manual compression. Technical success was achieved in 49 patients (94%). Forty-five patients (87%) were discharged on the first postoperative day. There were no complications of the access arteries one day or one month postoperatively, as determined by ultrasonography and computed tomography examinations, respectively. The mean diameters of the access arteries prior to and one month after the procedure were unchanged, as demonstrated by computed tomography.
Conclusion: Ultrasound-guided puncture of the common femoral artery for percutaneous closure of the access site has a high technical success rate and a very low complication rate. The addition of ultrasound guidance decreases the difficulty of the procedure and helps to avoid some of its complications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4261/1305-3825.DIR.4061-10.1 | DOI Listing |
Ann Thorac Surg Short Rep
March 2023
Department of Congenital Cardiothoracic Surgery, NYU Grossman School of Medicine, NYU Langone Health, New York, New York.
Modified Blalock-Thomas-Taussig shunts are typically performed with biosynthetic polytetrafluoroethylene grafts. However, biologic conduits are being increasingly investigated. We herein report a case in which a femoral artery homograft was effectively used as material for a Blalock-Thomas-Taussig shunt.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
Department of Cardiology, Tokai University School of Medicine, Isehara, Japan.
Toxicol Appl Pharmacol
January 2025
Institute of Medical Sciences, Department of Physiology, Kangwon National University School of Medicine, Chuncheon 24341, South Korea. Electronic address:
This study explored the vasodilatory mechanisms of the sodium-glucose cotransporter-2 inhibitor remogliflozin using femoral arteries of rabbits. Remogliflozin dilated femoral arterial rings pre-contracted with phenylephrine in a concentration-dependent manner. Pretreatment with the Ca-sensitive K channel inhibitor (paxilline), the ATP-sensitive K channel inhibitor (glibenclamide), or the inwardly rectifying K channel inhibitor (Ba) did not alter the vasodilatory effect.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Wake Forest University School of Medicine, Winston-Salem, NC, USA.
Background: Obesity is associated with adverse changes in the structure and function of both the brain and the vasculature and may modify risk for Alzheimer's disease (AD). However, the degree to which excess total and central adiposity contribute to overall disease burden in late-life is unclear. We investigated baseline associations between obesity, AD-related pathology, and neurovascular health in 255 participants enrolled in the U.
View Article and Find Full Text PDFCardiol Young
January 2025
University of Child Health Sciences, The Children's Hospital, Lahore, Pakistan.
We report a case of right ventricle to pulmonary artery conduit angioplasty in which a valvuloplasty balloon ruptured circumferentially and was retained within the conduit. A high-pressure balloon was used to relieve the obstruction and free the ruptured balloon. The procedure was further complicated when the distal part of the balloon broke away from the proximal part during an attempt to retrieve it back into the femoral sheath.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!