We have developed a haptic-based approach for retraining of interjoint coordination following stroke called time-independent functional training (TIFT) and implemented this mode in the ARMin III robotic exoskeleton. The ARMin III robot was developed by Drs. Robert Riener and Tobias Nef at the Swiss Federal Institute of Technology Zurich (Eidgenossische Technische Hochschule Zurich, or ETH Zurich), in Zurich, Switzerland. In the TIFT mode, the robot maintains arm movements within the proper kinematic trajectory via haptic walls at each joint. These arm movements focus training of interjoint coordination with highly intuitive real-time feedback of performance; arm movements advance within the trajectory only if their movement coordination is correct. In initial testing, 37 nondisabled subjects received a single session of learning of a complex pattern. Subjects were randomized to TIFT or visual demonstration or moved along with the robot as it moved though the pattern (time-dependent [TD] training). We examined visual demonstration to separate the effects of action observation on motor learning from the effects of the two haptic guidance methods. During these training trials, TIFT subjects reduced error and interaction forces between the robot and arm, while TD subject performance did not change. All groups showed significant learning of the trajectory during unassisted recall trials, but we observed no difference in learning between groups, possibly because this learning task is dominated by vision. Further testing in stroke populations is warranted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1682/jrrd.2010.04.0064 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
College of Computer Science and Technology, Xi'an University of Science and Technology, Xi'an 710054, China.
Soft and stretchable strain sensors are crucial for applications in human-machine interfaces, flexible robotics, and electronic skin. Among these, capacitive strain sensors are widely used and studied; however, they face challenges due to material and structural constraints, such as low baseline capacitance and susceptibility to external interference, which result in low signal-to-noise ratios and poor stability. To address these issues, we propose a U-shaped electrode flexible strain sensor based on liquid metal elastomer (LME).
View Article and Find Full Text PDFMov Disord
January 2025
Department of Neurology, LMU University Hospital, Ludwig-Maximilians-Universität (LMU) München, Munich, Germany.
Background: The recent Movement Disorders Society (MDS)-progressive supranuclear palsy (PSP) diagnostic criteria conceptualized three clinical diagnostic certainty levels: "suggestive of PSP" for sensitive early diagnosis based on subtle clinical signs, "possible PSP" balancing sensitivity and specificity, and "probable PSP" highly specific for PSP pathology.
Objective: The aim of this study was to prospectively validate the criteria against long-term clinical follow-up and characterize the diagnostic certainty increase over time.
Methods: Patients with "possible PSP" or "suggestive of PSP" diagnosis and clinical follow-up were recruited in two German multicenter longitudinal observational studies (ProPSP and DescribePSP).
J Clin Med
December 2024
Hand and Occupational Therapy Outpatient Service Laborn, 80802 München, Germany.
: To assess the effects of a two-week course of intensive impairment-oriented arm rehabilitation for chronic stroke survivors on motor function. : An observational cohort study that enrolled chronic stroke survivors (≥6 months after stroke) with mild to severe arm paresis, who received a two-week course of impairment-oriented and technology-supported arm rehabilitation (1:1 participant-therapist setting), which was carried out daily (five days a week) for four hours. The outcome measures were as follows: the primary outcome was the arm motor function of the affected arm (mild paresis: BBT, NHPT; severe paresis: Fugl-Meyer arm motor score).
View Article and Find Full Text PDFSensors (Basel)
December 2024
Assessment of Movement Behaviours (AMBer), Leicester Lifestyle and Health Research Group, Diabetes Research Centre, University of Leicester, Leicester LE5 4PW, UK.
Background: Following shoulder surgery, controlled and protected mobilisation for an appropriate duration is crucial for appropriate recovery. However, methods for objective assessment of sling wear and use in everyday living are currently lacking. In this pilot study, we aim to determine if a sling-embedded triaxial accelerometer and/or wrist-worn sensor can be used to quantify arm posture during sling wear and adherence to sling wear.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Engineering for Health Research Centre, Aston University, Aston Triangle, Birmingham B4 7ET, UK.
Human hands have over 20 degrees of freedom, enabled by a complex system of bones, muscles, and joints. Hand differences can significantly impair dexterity and independence in daily activities. Accurate assessment of hand function, particularly digit movement, is vital for effective intervention and rehabilitation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!