This study investigated whether three different color change light-cured orthodontic bonding adhesives have comparable shear bond strengths to a conventional light-cured orthodontic bonding adhesive. The sample of 240 bovine incisors was divided into four groups of 60 each. Each group tested one of four orthodontic bonding adhesives: 3M Unitek Transbond PLUS, Ormco Gréngloo, Ormco Blúgloo, and 3M Unitek Transbond XT (control). The four groups were further divided into two subgroups of 30 with shear bond strength tested at two different times (15 minutes and 24 hours) post-bond. The shear bond strength was measured on a universal testing machine. The data were analyzed by two-way analysis of variance and post-hoc comparisons (Fisher's PLSD) at the 0.05 level of significance. The average shear bond strength was greater at 24 hours than at 15 minutes for Transbond PLUS, Blúgloo, and Transbond XT. For Gréngloo, the average shear bond strength was greater at 15 minutes than at 24 hours. Gréngloo tested at 15 minutes had the highest average shear bond strength. Gréngloo tested at 24 hours had the lowest average shear bond strength. All four orthodontic bonding adhesives demonstrated bond strengths considered to be clinically acceptable for orthodontic purposes.

Download full-text PDF

Source

Publication Analysis

Top Keywords

bond strength
28
shear bond
28
orthodontic bonding
20
average shear
16
bonding adhesives
12
bond
9
color change
8
light-cured orthodontic
8
bond strengths
8
unitek transbond
8

Similar Publications

Effect of Irrigation Solution Temperature on Bioceramic Sealer Bond Strength.

Med Sci Monit

January 2025

Department of Endodontics, Faculty of Dentistry, Dicle University, Diyarbakir, Turkey.

BACKGROUND Different temperature conditions can affect the efficiency of irrigation solutions and consequently the ability of canal sealers to bond to root canal walls. The aim of this endodontic study was to evaluate the effect of irrigation solutions at different temperatures on the bond strength of a bioceramic-based root canal sealer. MATERIAL AND METHODS Root canal preparations were completed through irrigation with the following solutions: Group 1 was irrigated with 5 ml NaOCl (sodium hypochlorite) +5 ml EDTA (Ethylenediamine tetra-acetic acid) (22°C); Group 2 was irrigated with 5 ml NaOCl +5 ml EDTA (37°C); Group 3 was irrigated with 5 ml NaOCl +5 ml GA (Glycolic acid) (22°C); Group 4 was irrigated with 5 ml NaOCl +5 ml GA (37°C), Group 5 was irrigated with 20 ml Dual Rinse® HEDP (Etidronate) - NaOCl mixture (22°C); and Group 6 was irrigated with 20 ml of Dual Rinse® HEDP mixture (37°C).

View Article and Find Full Text PDF

A comparative study of polydopamine vs. glass ionomer cement for adhesion mechanisms on enamel and dentin using SEM and shear bond strength evaluation.

Sci Rep

January 2025

Department of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, 600077, India.

Polydopamine (PD), inspired by the wet adhesion mechanism of mussel foot proteins, has emerged as a promising adhesive material with wide-ranging applications. This study aimed to compare the adhesive properties of PD and Glass Ionomer Cement (GIC) on enamel and dentin substrates, evaluating PD's potential as an alternative adhesive in dental practice. A total of 120 human premolars were prepared, with 80 teeth allocated for Scanning Electron Microscopy (SEM) analysis and 40 teeth reserved for shear bond strength testing.

View Article and Find Full Text PDF

Effect of Application Mode and Aging on Microtensile Bond Strength of Universal Adhesives to Enamel of Primary Teeth.

Int J Paediatr Dent

January 2025

Department of Paediatric Dentistry, Medical Centre for Dentistry, University Medical Centre Giessen and Marburg GmbH (Campus Giessen), Justus-Liebig-University, Giessen, Germany.

Background: Limited reports are available regarding bonding of universal adhesives to primary teeth' enamel.

Aim: To evaluate the effect of application mode and aging on microtensile bond strength (μTBS) of universal adhesives to primary enamel.

Design: Ninety-six human primary molars were randomly assigned to three groups: SU: Scotchbond Universal (3M); CU: Clearfil Universal Bond Quick (Kuraray Noritake); iBU: iBond Universal (Heraeus Kulzer), then subdivided according to phosphoric acid etching time into three subgroups (SG): SG1: 0s; SG2: 15s; SG3: 30s.

View Article and Find Full Text PDF

Ingeniously regulating the conformational equilibrium and ESPT mechanism of HBT-DPI by solvent environment: A novel perspective.

Spectrochim Acta A Mol Biomol Spectrosc

January 2025

Jilin Key Laboratory of Solid-State Laser Technology and Application, School of Physics, Changchun University of Science and Technology, Changchun 130022 China. Electronic address:

HBT-DPI was a single-molecule multi-conformational fluorescent material and had unique applications for hydrophobic/hydrophilic mapping on large-scale heterogeneous surfaces. In this paper, the different proton transfer processes and luminescence mechanisms of HBT-DPI in Dichloromethane (DCM, no hydrogen bond (HB) receptor) and N, N-Dimethylformamide (DMF, HB receptor) solvents were systematically studied. Using the quantum chemistry method, the stable structures of HBT-DPI in two solvents were determined based on the Boltzmann distribution.

View Article and Find Full Text PDF

Inserted-B atoms modulating electronic structure of Pt enhancing hydrogen evolution under Universal-pH.

J Colloid Interface Sci

January 2025

College of Materials Science and Engineering, Fuzhou University, Fuzhou 350108 China. Electronic address:

The development of high-performance electrocatalysts for hydrogen evolution reaction (HER) in different pH conditionsis pivotal in producing green hydrogen, but remains challenging. Herein, we regulate the p-d orbitals hybridization between B and Pt for effective and durable HER at all pH ranges by controlling the inserted B atom. Consequently, the optimized B-doped Pt catalysts with 20 at.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!