A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Carotid to femoral pulse wave velocity: a comparison of real travelled aortic path lengths determined by MRI and superficial measurements. | LitMetric

Objectives: Carotid-femoral pulse wave velocity (PWV) is the gold standard method for determination of arterial stiffness. PWV is assessed by dividing travelled distance by travel time. Standardization and validation of the methodology for travelled distance measurement is of crucial importance. The aim of the current investigation was to standardize and validate the methodology for travelled distance measurement.

Methods: Real travelled carotid-femoral path lengths were measured with MRI in 98 healthy men/women (50% men, age 21-76 years) and are used as reference distance. This reference distance was compared with 11 estimates of aortic path length from body surface distances commonly used in PWV measurement, nine of them based on tape measures and two based on body height. Determinants of the difference between reference distance and the best body surface distance were determined. Additionally, the influence of body contours was identified.

Results: The tape measure distance from carotid to femoral artery (CA-FA), multiplied by 0.8, yielded the best agreement with the reference aortic path length [difference 0.26 cm (SD 3.8), not statistically significant]. Thirty percent of the variation in difference between the reference distance and tape measure distance (CA-FA × 0.8) was explained by age. Adding BMI increased this number to 34%.

Conclusion: The tape measure distance from CA-FA, multiplied by 0.8, corresponds best with the real travelled aortic path length. This distance is moderately (yet statistically significantly) influenced by age and minimally by BMI.

Download full-text PDF

Source
http://dx.doi.org/10.1097/HJH.0b013e3283487841DOI Listing

Publication Analysis

Top Keywords

aortic path
16
reference distance
16
real travelled
12
distance
12
travelled distance
12
path length
12
tape measure
12
measure distance
12
carotid femoral
8
pulse wave
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!