Despite numerous reports on biocide activities, it is often difficult to have a reliable and relevant overview of bacterial resistance to disinfectants because each work challenges a limited number of strains and tested methods are often different. The aim of this study was to evaluate the bactericidal activity of three different disinfectants commonly used in industrial or medical environments (peracetic acid, benzalkonium chloride and ortho-phthalaldehyde) against 77 bacterial strains from different origins using one standard test method (NF EN 1040). Results highlight the existence of high interspecific variability of resistance to disinfectants and, contrary to widespread belief, Gram-positive strains generally appeared more resistant than Gram-negative strains. Resistance was also variable among strains of the same species such as Bacillus subtilis to peracetic acid, Pseudomonas aeruginosa to benzalkonium chloride and Staphylococcus aureus to ortho-phthalaldehyde.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhin.2011.03.014DOI Listing

Publication Analysis

Top Keywords

peracetic acid
12
benzalkonium chloride
12
acid benzalkonium
8
chloride ortho-phthalaldehyde
8
ortho-phthalaldehyde bacterial
8
bacterial strains
8
resistance disinfectants
8
strains
6
comparative biocidal
4
biocidal activity
4