The aim of the study was to investigate changes in volumetric capnography (V(C)) variables during bronchoconstriction in dogs and compare it with total respiratory resistance (R(L)) measured with a Fleisch pneumotachograph. Six dogs were challenged with increasing concentrations of carbachol until obvious signs of bronchoconstriction were seen. All V(C) parameters were obtained before, directly after, 10 and 20 min after maximal bronchoconstriction. The slope of phase III (SIII) and airway and alveolar dead space parameters were significantly different from baseline directly after the challenge. The V(C) curve obtained a typical shape at the time of maximal bronchoconstriction and a trend to return to baseline shape was seen over time. A significant correlation was found for all aforementioned parameters with R(L). We conclude that the shape of the V(C) curve in combination with dead space calculation can be used to verify bronchoconstriction on a breath-to-breath basis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rvsc.2011.05.014DOI Listing

Publication Analysis

Top Keywords

volumetric capnography
8
bronchoconstriction dogs
8
maximal bronchoconstriction
8
dead space
8
shape time
8
bronchoconstriction
6
evaluation variables
4
variables describe
4
shape
4
describe shape
4

Similar Publications

To investigate the feasibility of non-invasively estimating the arterial partial pressure of carbon dioxide (PaCO) using a computational Adaptive Neuro-Fuzzy Inference System (ANFIS) model fed by noninvasive volumetric capnography (VCap) parameters. In 14 lung-lavaged pigs, we continuously measured PaCO with an optical intravascular catheter and VCap on a breath-by-breath basis. Animals were mechanically ventilated with fixed settings and subjected to 0 to 22 cmHO of positive end-expiratory pressure steps.

View Article and Find Full Text PDF

Capnography, routinely used in operating rooms and intensive care units, reveals essential information on lung ventilation and ventilation-perfusion matching. Mainstream capnography directly measures CO in the breathing circuit for accurate analysis and is considered a reference technique. Sidestream capnography, however, analyzes gas away from the patient leading to potentially less accurate measures.

View Article and Find Full Text PDF

Objective: To compare the portion of tidal volume (V) ventilating dead space volumes in nonbrachycephalic cats and dogs with small body mass receiving volume-controlled ventilation (VCV) with a fixed V.

Study Design: Prospective, experimental study.

Animals: A group of eight healthy adult cats and dogs [ideal body weight (IBW): 3.

View Article and Find Full Text PDF

Background: The bedside diagnosis of acute pulmonary edema is challenging. This study evaluated the breath-by-breath information from electrical impedance tomography (EIT), respiratory mechanics and volumetric capnography (VCap) to assess acute pulmonary edema induced by xylazine administration in anesthetized sheep.

Objective: To determine the ability and efficiency of each monitoring modality in detecting changes in lung function associated with onset of pulmonary edema.

View Article and Find Full Text PDF

Chronic Obstructive Pulmonary Disease (COPD), as the third leading cause of death worldwide, is a major global health issue. The early detection and grading of COPD are pivotal for effective treatment. Traditional spirometry tests, requiring considerable physical effort and strict adherence to quality standards, pose challenges in COPD diagnosis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!