Background/purpose: To augment the accuracy of stereotactic body radiation therapy (SBRT), a variety of image guidance systems are used for patient positioning and target localization. Clinical outcomes evaluating these systems, especially frameless image-guided systems, are still limited. This article aims to describe and evaluate our frameless image-guided SBRT technique for lung tumors.

Methods: Between 2007 and 2009, 85 pulmonary tumors (50 primaries and 35 metastases) were treated with SBRT using daily image guidance for patient positioning and target localization in lieu of a body frame. Four-dimensional computed tomography (4DCT) or an in-house protocol for integrated 4D positron emission computed tomography (4DPET/CT) was used for planning simulation.

Results: Median follow-up was 17 months (range, 4-42). Median overall survival (OS) was 31 months (95% CI, 26-34), and median local failure-free survival was 30 months (95% CI, 18-32). At last follow-up, 9 of 83 evaluable lesions failed locally. Actuarial local control at 24 months was 87% (95% CI, 75-98) and was significantly worse for metastatic lesions (95% vs. 74%; P = .045; log-rank test). No acute or late toxicities (grade ≥ 4) were observed.

Conclusions: Frameless image-guided SBRT is a feasible, safe, and effective treatment for lung tumors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cllc.2011.03.014DOI Listing

Publication Analysis

Top Keywords

frameless image-guided
16
computed tomography
16
stereotactic body
8
body radiation
8
radiation therapy
8
lung tumors
8
positron emission
8
image guidance
8
patient positioning
8
positioning target
8

Similar Publications

Objectives: To evaluate the precision and safety of a novel technique of free-hand frameless pinless AXIEM™-based navigation guided biopsy of deep-seated brain lesions in a low-middle income country.

Methods: This retrospective study included 45 patients who underwent free-hand frameless pinless AXIEM™-based navigation guided biopsy of deep-seated brain lesions using the Medtronic-Stealth S7 system over a 5-year period (January 2019 to December 2023) at the Department of Neurosurgery, Punjab Institute of Neurosciences, Lahore, Pakistan.

Results: A total of 45 patients were included in this study.

View Article and Find Full Text PDF

Introduction: Non-invasive frameless systems have paved its way for stereotactic radiotherapy treatments compared to gold standard invasive rigid frame-based systems as they are comfortable to patients, do not have risk of pain, bleeding, infection, frame slippage and have similar treatment efficacy.

Aim And Objective: To estimate immobilisation accuracy (interfraction and intrafraction) and PTV margins with double shell positioning system (DSPS) using daily image guidance for stereotactic radiotherapy in patients with brain tumors.

Materials And Method: A prospective study was done in 19 cranial tumor patients with KPS ≥70, immobilized by the DSPS with mouth bite and treated with LINAC based image guided stereotactic radiotherapy.

View Article and Find Full Text PDF

Purpose: The aim of this study was to assess the accuracy of a surface-guided radiotherapy (SGRT) system for setup and intra-fraction motion control in frameless non-coplanar stereotactic radiosurgery (fSRS) using actual patient data immobilized with two different types of open-faced masks and employing a novel SGRT systems settings.

Methods And Materials: Forty-four SRS patients were immobilized with two types of open-faced masks. Sixty lesions were treated, involving the analysis of 68 cone-beam scans (CBCT), 157 megavoltage (MV) images, and 521 SGRT monitoring sessions.

View Article and Find Full Text PDF

Purpose: Precision targeting is crucial to successful stereotactic radiosurgery for trigeminal neuralgia (TGN). We investigated the impact of intra-fractional 6-dimensional corrections during frameless image-guided radiosurgery (IGRS) for pain outcome in TGN patients.

Materials And Methods: A total of 41 sets of intra-fractional corrections from 35 patients with TGN treated by frameless IGRS from 2009 to 2013 were retrospectively studied.

View Article and Find Full Text PDF

Impact of Fractionation Regimen on Local Control Following Frameless Linear Accelerator-Based Image-Guided Stereotactic Radiosurgery and Radiotherapy for Intracranial Meningioma.

World Neurosurg

October 2024

Department of Radiation Oncology, Southern California Permanente Medical Group, Los Angeles, California, USA; Department of Clinical Sciences, Kaiser Permanente Bernard J. Tyson School of Medicine, Pasadena, California, USA. Electronic address:

Objective: Stereotactic radiosurgery (SRS) is an established treatment for intracranial meningioma, yet this approach is often precluded by tumor size or proximity to critical structures. Fractionated radiotherapy (RT) may be employed to address these limitations. We performed a comparison of local control (LC) outcomes between 3 stereotactic techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!