A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Safety and feasibility of a novel transcervical access neuroprotection system for carotid artery stenting in the PROOF Study. | LitMetric

Background: Randomized controlled trials have shown that periprocedural rates of stroke and death are higher with carotid artery stenting (CAS) than with carotid endarterectomy (CEA) in the treatment of carotid artery stenosis. Diffusion-weighted magnetic resonance imaging (DW-MRI) has shown higher rates of clinically silent new ischemic brain lesions when CAS is performed as compared with CEA. The Silk Road Medical Embolic PROtectiOn System: First-In-Man (PROOF) Study is a single-arm first-in-man study using the MICHI Neuroprotection System (Silk Road Medical Inc, Sunnyvale, Calif), a novel transcervical access and cerebral embolic protection system. This system enables stent implantation under controlled blood flow reversal of the carotid artery, also known as Flow Altered Short Transcervical Carotid Artery Stenting (FAST-CAS).

Methods: Between March 2009 and February 2010, a total of 44 subjects were enrolled into the study. The primary composite endpoint was major stroke, myocardial infarction, or death within 30 days. Forty-three patients (97.7%) completed the study through the 30-day endpoint. One patient was lost to follow-up. In a subgroup of consecutive subjects, DW-MRI examinations were performed preprocedure and within 24 to 48 hours after the stent implantation. Blinded independent neuroradiologists reviewed all DW-MRI studies and confirmed the absence or presence of new ischemic brain lesions.

Results: All enrolled patients were successfully treated, and no major adverse events were seen through the follow-up period. Thirty-one subjects had DW-MRI examinations. Of these, five patients (16%) had evidence of new ischemic brain lesions but no clinical sequelae. Transient intolerance to reverse flow was reported in 9% of cases, but in all cases, a stent was successfully placed, and the intolerance was managed by minimizing the duration of reverse flow during the procedure.

Conclusion: In this first-in-man experience, FAST-CAS using the MICHI Neuroprotection System was shown to be a safe and feasible method for carotid revascularization. DW-MRI findings suggest controlled reverse flow provides cerebral embolic protection similar to that seen with CEA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2011.04.040DOI Listing

Publication Analysis

Top Keywords

carotid artery
20
neuroprotection system
12
artery stenting
12
ischemic brain
12
embolic protection
12
reverse flow
12
novel transcervical
8
transcervical access
8
proof study
8
brain lesions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!