The aim of this study was to establish the optimal methodology for skin-fixed measurement of the scapula during dynamic movement. This was achieved by comparing an optimally positioned Scapula Tracker device (ST) to a previously described palpation device, taken as the true measure of scapular kinematics. These measurements were compared across a range of calibration positions, including the use of multiple calibration positions for a single movement, in order to establish an optimal calibration approach. Ten subjects' scapular motion was measured using this ST and a previously described Acromial Method (AM). The two datasets were compared at a standard, an optimal and a 'multiple' calibration position, thus allowing a direct comparison between two common skin-fixed methods to track the bony kinematics of the scapula across different calibration positions. A comparison was also made with a bone-fixed technique from the literature. At both the standard and optimal calibration positions the ST was shown to be the more accurate measure of internal rotation and posterior tilt, particularly above 100° of humerothoracic elevation. The ST errors were found to be acceptable in relation to clinically important levels. Calibration positions have been shown to have a significant effect on the errors of both skin-fixed measurement techniques and therefore the importance of correct calibration is highlighted. It has thus been shown that a ST can be used to accurately quantify scapular motion when appropriately calibrated for the range of motion being measured.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2011.05.010DOI Listing

Publication Analysis

Top Keywords

calibration positions
24
calibration
9
range calibration
8
establish optimal
8
skin-fixed measurement
8
optimal calibration
8
scapular motion
8
motion measured
8
standard optimal
8
positions
6

Similar Publications

Background: The development of wearable solutions for tracking upper limb motion has gained research interest over the past decade. This paper provides a systematic review of related research on the type, feasibility, signal processing techniques, and feedback of wearable systems for tracking upper limb motion, mostly in rehabilitation applications, to understand and monitor human movement.

Objective: The aim of this article is to investigate how wearables are used to capture upper limb functions, especially related to clinical and rehabilitation applications.

View Article and Find Full Text PDF

Sea ice is a key element of the global Earth system, with a major impact on global climate and regional weather. Unfortunately, accurate sea ice modeling is challenging due to the diversity and complexity of underlying physics happening there, and a relative lack of ground truth observations. This is especially true for the Marginal Ice Zone (MIZ), which is the area where sea ice is affected by incoming ocean waves.

View Article and Find Full Text PDF

Purpose: The goal of this study was to assess the feasibility of a cost-effective prototype of a laser-based respiratory motion detection system utilizing a Leuze LDS for breath monitoring through calibration and volunteer tests.

Methods: This study was performed using the Anzai AZ-773 V and computerized imaging reference systems (CIRS) motion phantoms for calibration tests. The calibration of the laser-based respiratory motion detection system involved spatial accuracy testing, amplitude calibration, and temporal accuracy.

View Article and Find Full Text PDF

Introduction: Myoelectric control systems translate different patterns of electromyographic (EMG) signals into the control commands of diverse human-machine interfaces via hand gesture recognition, enabling intuitive control of prosthesis and immersive interactions in the metaverse. The effect of arm position is a confounding factor leading to the variability of EMG characteristics. Developing a model with its characteristics and performance invariant across postures, could largely promote the translation of myoelectric control into real world practice.

View Article and Find Full Text PDF

Vomer-to-nasopharyngeal widths and post-adenoidectomy outcomes in children: A prospective blinded study.

Int J Pediatr Otorhinolaryngol

December 2024

Department of Otolaryngology-Head and Neck Surgery, Rambam Health Care Campus, Haifa, Israel; Ruth and Bruce Rappaport Faculty of Medicine, Technion, Haifa, Israel.

Objectives: The vomer is an essential component of the nasopharynx. Although variations in vomer width(VW) and nasopharyngeal width(NW) can be observed, their clinical significance on post-adenoidectomy outcomes in children with sleep-disordered breathing and obstructive sleep apnea(SDB-OSA) remains uncertain. The primary outcome was to investigate the association between VW and post-adenoidectomy clinical improvement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!