Screening for vancomycin-resistant enterococci: an efficient and economical laboratory-developed test.

Eur J Clin Microbiol Infect Dis

Division of Clinical Microbiology, Department of Laboratory Medicine, Karolinska University Hospital Huddinge, Karolinska Institute, 141 86, Stockholm, Sweden.

Published: March 2012

A laboratory-developed test (Lab Assay), combining enrichment broth and real-time polymerase chain reaction (PCR) for vancomycin-resistant enterococci (VRE) screening, was developed and evaluated in this study. A total of 1,765 faecal or rectal swabs sent to the laboratory for VRE screening were investigated in parallel by Lab Assay and the Roche LightCycler VRE detection kit-based method. The diagnostic values for Lab Assay were as follows: 100% sensitivity, 79.92% specificity, 1.94% positive predictive value and 100% negative predictive value, which were comparable to the results from the LightCycler kit-based assay. The detection limit of Lab Assay was 10(0) to 10(1) colony-forming units (CFU)/ml of inoculum in broth for both VanA-type and VanB-type VRE. The PCR method developed in this study was approved to be applicable on both the Applied Biosystems 7500 Fast Real-Time PCR System and the LightCycler(®) 480 Real-Time PCR System. The flexibility in choosing PCR systems makes it possible that the PCR assay could be fully compatible with the DNA extraction's platform, providing an integrated workflow. Furthermore, the material cost is saved at 7EUR per sample when Lab Assay replaces the commercial kit-based method in our routine screening for VRE. Therefore, the laboratory-developed broth-PCR method is an efficient and economical assay for VRE screening.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10096-011-1304-0DOI Listing

Publication Analysis

Top Keywords

lab assay
20
vre screening
12
vancomycin-resistant enterococci
8
efficient economical
8
laboratory-developed test
8
assay
8
kit-based method
8
real-time pcr
8
pcr system
8
pcr
6

Similar Publications

Background: Accurate assessment of cardiovascular disease (CVD) risk is crucial for effective prevention and resource allocation. However, few CVD risk estimation tools consider social determinants of health (SDoH), despite their known impact on CVD risk. We aimed to estimate 10-year CVD risk in the Eastern Caribbean Health Outcomes Research Network Cohort Study (ECS) across multiple risk estimation instruments and assess the association between SDoH and CVD risk.

View Article and Find Full Text PDF

Background: Direct oral anticoagulants (DOACs) can interfere with coagulation analyses, causing erroneous results such as false-positive lupus anticoagulant and false-normal antithrombin, threatening patient safety when overlooked. A test using a prothrombin time quotient method to detect DOAC presence in plasma samples is now commercially available, the MRX PT DOAC, with the result expressed as Clot Time Ratio (CTR).

Objectives: Evaluate the ability of MRX PT DOAC to identify interfering apixaban or rivaroxaban concentrations, identify non-interfering or interfering patient samples, and detect whether a patient is on DOAC treatment.

View Article and Find Full Text PDF

Development of Synthetic Antimicrobial Peptides Based on Genomic Analysis of Streptococcus salivarius.

J Clin Lab Anal

January 2025

Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.

Background: In the oral environment, the production of bacteriocins or antimicrobial peptides (AMPs) plays a crucial role in maintaining ecological balance by impeding the proliferation of closely related microorganisms. This study aims to conduct in silico genome screening of Streptococcus salivarius to identify potential antimicrobial compounds existing as hypothetical peptides, with the goal of developing novel synthetic antimicrobial peptides.

Methods: Draft genomes of various oral Streptococcus salivarius strains were obtained from the NCBI database and subjected to analysis using bioinformatic tools, viz.

View Article and Find Full Text PDF

Background: Post-activation performance enhancement (PAPE) has demonstrated efficacy in acutely improving athletic performance. However, its distinction from general warm-up (GW) effects remains ambiguous, and experimental designs adopted in most PAPE studies exhibit important limitations.

Objectives: The aims of this work are to (i) examine the effects of research methodology on PAPE outcomes, (ii) explore PAPE outcomes in relation to comparison methods, performance measures, GW comprehensiveness, recovery duration, participants' characteristics, conditioning activity (CA) parameters, and (iii) make recommendations for future PAPE experimental designs on the basis of the results of the meta-analysis.

View Article and Find Full Text PDF

Purpose: Retinal vein occlusion (RVO) is a prevalent retinal vascular disorder characterized by retinal haemorrhage, neovascularization, and macular edema This study aimed to assess the structural and functional effects of intravitreal implant (Ozurdex) treatment as a second-line for RVO-associated macular edema in patients who did not respond to first-line anti-VEGF therapy.

Materials And Methods: We conducted a retrospective observational cohort study using electronic health records of RVO patients at Salisbury District Hospital between January 2014 and December 2019. Inclusion criteria included patients diagnosed with central or branch RVO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!