Formation of OTS self-assembled monolayers at chemically treated titanium surfaces.

J Mater Sci Mater Med

School of Engineering and Materials Science, Queen Mary, University of London, London, E1 4NS, UK.

Published: August 2011

Enhanced biocompatibility of titanium implants highly depends on the possibility of achieving high degrees of surface functionalization for a low immune response and/or enhanced mineralization of bioactive minerals, such as hydroxyapatite. In this respect, surface modification with Self Assembled Monolayers (SAMs) has a great potential in delivering artificial surfaces of improved biocompatibility. Herein, the effectiveness of common chemical pre-treatments, i.e. hydrogen peroxide (H(2)O(2)) and Piranha (H(2)SO(4) + H(2)O(2)), in facilitating surface decontamination and hydroxylation of titanium surfaces to promote further surface functionalization by SAMs is investigated. The quality of the octadecyltrichlorosilane (OTS) based SAM appeared to strongly depend upon the surface morphology, the density and nature of surface hydroxyl sites resulting from the oxidative pre-treatments. Contrary to common belief, no further hydroxylation of the titanium substrate was observed after the selected chemical pre-treatments, but the number of hydroxyl groups available on the surface was decreased as a result of the formation of a titanium oxide layer with a gel-type structure. Further examinations by atomic force microscopy, infrared spectroscopy and X-ray photoelectron spectroscopy also revealed that mild oxidizing conditions were sufficient to remove surface contamination without detrimental effects on surface hydroxylation state and surface roughness. Furthermore, the adsorption of the alkylsiloxane molecules forming the SAM film is believed to proceed through hydrolysis at surface acidic hydroxyl groups rather than randomly. This site dependent adsorption process has significant implications for further functionalization of titanium based implants. It also highlights the difficulty of achieving an OTS based SAM at the surface of titanium and question the quality of SAMs reported at titanium surfaces so far.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10856-011-4356-xDOI Listing

Publication Analysis

Top Keywords

titanium surfaces
12
surface
12
titanium
8
surface functionalization
8
chemical pre-treatments
8
hydroxylation titanium
8
ots based
8
based sam
8
hydroxyl groups
8
formation ots
4

Similar Publications

Research on titanium nanotubes modified with metal sulfides, particularly bismuth sulfide (BiS), aims to create heterostructures that efficiently absorb sunlight and then separate photogenerated charge carriers, thereby enhancing the energy conversion efficiency. This study shows a key role of solvent used for sulfide and bismuth salt solutions used during successive ionic layer adsorption and reaction (SILAR) onto the morphology, structure, and photoresponse of the heterojunction where one element is represented by semitransparent titania nanotubes (gTiNT) and the second is BiS. Using 2-methoxyethanol and methanol during SILAR, results in remarkably photoactive 3D heterostructure and recorded photocurrents were 44 times higher compared to bare titania nanotubes.

View Article and Find Full Text PDF

First-principles study of CO and HO adsorption on the anatase TiO(101) surface: effect of Au doping.

Phys Chem Chem Phys

January 2025

Shanxi Coal International Energy Group Co., Ltd., Taiyuan 030000, China.

Photocatalytic reduction of CO will play a major role in future energy and environmental crisis. To investigate the adsorption mechanisms of CO and HO molecules involved in the catalytic process on the surface of anatase titanium dioxide 101 (TiO(101)) and the influence of Au atom doping on their adsorption, first-principles density functional theory calculations were used. The results show that 1.

View Article and Find Full Text PDF

Background: Implant fixation is often the cornerstone of musculoskeletal surgical procedures performed to provide bony fixation and/or fusion. The aim of this study was to evaluate how different design features and manufacturing methods influence implant osseointegration and mechanical properties associated with fixation in a standardized model in cancellous bone of adult sheep.

Methods: We evaluated the performance of three titanium alloy implants: (A) iFuse-TORQ implant; (B) Fenestrated Sacroiliac Device; and (C) Standard Cancellous Bone Screw in the cancellous bone of the distal femur and proximal tibia in 8 sheep.

View Article and Find Full Text PDF

Objectives: This study aimed to compare the marginal adaptation of a cold ceramic (CC) sealer with the single-cone obturation technique with that of an AH-26 sealer with the lateral compaction technique in single-canal teeth.

Materials And Methods: In this in vitro experimental study, the root canals of 24 extracted single-rooted single-canal teeth were instrumented to F3 files by the crown-down technique and randomly assigned to 2 groups (n = 12). The root canals were obturated with a CC sealer and single-cone obturation technique with 4% gutta-percha in group 1 and with an AH-26 sealer and lateral compaction technique with 2% gutta-percha in group 2.

View Article and Find Full Text PDF

Blood-contacting medical devices can easily trigger immune responses, leading to thrombosis and hyperblastosis. Constructing microtexture that provides efficient antithrombotic and rapid reendothelialization performance on complex curved surfaces remains a pressing challenge. In this work, we present a robust and regular micronano binary texture on the titanium surface, characterized by exceptional mechanical strength and precisely controlled wettability to achieve excellent hemocompatibility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!