A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Application of an electrolyzed strongly acidic aqueous solution before wound closure in colorectal surgery. | LitMetric

Background: Electrolyzed strongly acidic aqueous solution which is produced by electrolysis of a sodium chloride solution has been used in Japan for the irrigation of wounds or body cavities even in the absence of particular evidence.

Objective: The purpose of this study is to investigate the efficacy or harmful effects of the disinfectant when applied before wound closure in colorectal surgery.

Design: We performed a prospective, randomized study.

Setting: The study was conducted at Surgical Department of Hyogo College of Medicine

Patients: Patients who underwent elective colorectal surgery were randomly assigned to 2 groups. The surgical wound was irrigated with >500 mL of the disinfectant or saline solution after the completion of fascia closure. Patients with dirty/infected wounds were excluded from the study.

Main Outcome Measures: The primary end point of this study was comparison of the frequency of incisional surgical site infection. The secondary end point was the occurrence of wound dehiscence or wound hernia.

Results: One hundred eighty patients in the disinfectant group and 183 patients in the saline solution group were analyzed. In multivariate analysis, IBD and contaminated wounds were independent risk factors for incisional surgical site infection. Application of the disinfectant tended to lower the risk of the infection (OR 0.457, 95% CI 0.206-1.013). In the analysis of poor wound healing, preoperative hospital stay of >2 weeks, stoma creation, and use of the disinfectant (OR 2.28, 95% CI 1.03-5.04) were independent risk factors.

Limitation: This study was not a double-blind trial.

Conclusions: Application of electrolyzed strongly acidic aqueous solution to the wound impaired wound healing. Routine use of electrolyzed strongly acidic aqueous solution is not recommended in patients undergoing elective colorectal surgery. As for the contribution of the disinfectant to preventing wound infections, further study is needed to make a definitive conclusion.

Download full-text PDF

Source
http://dx.doi.org/10.1007/DCR.0b013e318211b83aDOI Listing

Publication Analysis

Top Keywords

electrolyzed acidic
16
acidic aqueous
16
aqueous solution
16
colorectal surgery
12
wound
9
application electrolyzed
8
solution wound
8
wound closure
8
closure colorectal
8
elective colorectal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!