Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A HPLC method with diode-array detection, at 265 nm, was developed and validated for the determination of ten sulfonamides (SAs): sulfadiazine (SDZ), sulfathiazine (STZ), sulfamethoxine (SMTH), sulfamethizole (SMZ), sulfamethoxypyridazine (SMPZ), sulfamonomethoxine (SMMX), sulfamethoxazole (SMXZ), sulfisoxazole (SIX), sulfadimethoxine (SDMX), and sulfaquinoxaline (SQX) in milk. A mixture of ethyl acetate, n-hexane, and isopropanol was used for the extraction of target analytes from milk. The mobile phase, a mixture of 0.1% v/v formic acid, CH(3) CN, and CH(3) OH was delivered to the analytical column under a gradient program. The procedure was validated according to the European Union regulation 2002/657/EC in terms of selectivity, stability, decision limit, detection capability, accuracy, and precision. Mean recoveries of sulfonamides from milk samples spiked at three concentration levels (0.5×MRL, 1×MRL, and 1.5×MRL) (MRL, maximum residue level) were 93.9-115.9% for SDZ, 97.8-102.9% for STZ, 94.6-107.0% for SMTH, 98.3-111.5% for SMZ, 95.3-108.4% for SMPZ, 97.9-106.0% for SMMX, 97.6-111.3% for SMXZ, 94.3-104.6% for SIX, 96.4-109.1% for SDMX, and 98.2-111.2% for SQX. All RSD values were lower than 8.8%. The decision limits CCa calculated by spiking 20 blank milk samples at MRL (100 μg/kg) ranged from 101.61 to 106.84 μg/kg, whereas the detection capability CCb ranged from 105.64 to 119.01 μg/kg.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jssc.201100171 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!