Introduction: Stem cell-based therapies are emerging as important and promising methods in the treatment of end-stage liver disease. This study is aimed to evaluate the effects of human umbilical cord blood mesenchymal stem cell (HUCBMSC) transplantation in acute hepatic necrosis (AHN).

Methods: Green fluorescent protein (GFP)-labeled HUCBMSCs were injected into the liver of rats in which AHN was induced by carbon tetrachloride, and the migration of these cells in liver slices was evaluated from 48 hours to 4 weeks post-transplantation. The transdifferentiation status of the HUCBMSCs was evaluated using immunohistochemistry and real-time reverse transcription-polymerase chain reaction, and survival rates were statistically analyzed.

Results: Dispersed GFP fluorescence was observed along the portal area 48 hours after transplantation. One week post-transplantation, GFP-positive cells were found in necrotic liver areas, and GFP-positive cells persisted after 4 weeks. Immunohistochemistry and real-time polymerase chain reaction analysis showed that transplanted HUCBMSCs expressed several human liver tissue-specific markers in rats with AHN. Statistical analysis revealed that rats with AHN that were transplanted with HUCBMSCs had significantly lower death rates after 48 hours than those receiving no HUCBMSCs.

Conclusion: HUCBMSC transplantation can significantly improve the survival of rats with AHN. The underlying mechanisms involved may include the transdifferentiation of HUCBMSCs into hepatocyte-like cells and targeted migration of these cells to liver lesion sites.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAJ.0b013e3182112b90DOI Listing

Publication Analysis

Top Keywords

rats ahn
16
human umbilical
8
umbilical cord
8
cord blood
8
blood mesenchymal
8
mesenchymal stem
8
survival rates
8
acute hepatic
8
hepatic necrosis
8
hucbmsc transplantation
8

Similar Publications

Extracellular vesicles (EVs) possess the characteristics of their parent cells, based on which various studies have actively investigated treatments for diseases using mesenchymal stem cell-derived EVs due to their regenerative activity. Furthermore, in recent years, there have been significant efforts to engineer EVs to improve their native activities and integrate additional functions. Although both endogenous and exogenous methods are used for engineering EVs, endogenous methods may pose the problem of administering substances to cells undergoing metabolic changes, which can cause potential side effects.

View Article and Find Full Text PDF

Non-Invasive Photoacoustic Cerebrovascular Monitoring of Early-Stage Ischemic Strokes In Vivo.

Adv Sci (Weinh)

December 2024

Departments of Convergence IT Engineering, Medical Science and Engineering, Electrical Engineering, and Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Cheongam-ro 77, Nam-gu, Pohang, Gyeongbuk, 37673, Republic of Korea.

Early-stage stroke monitoring enables timely intervention that is crucial to minimizing neuronal damage and increasing the extent of recovery. By monitoring collateral circulation and neovascularization after ischemic stroke, the natural recovery process can be better understood, optimize further treatment strategies, and improve the prognosis. Photoacoustic computed tomography (PACT), a non-invasive imaging modality that captures multiparametric high-resolution images of vessel structures, is well suited for evaluating cerebrovascular structures and their function.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the effect of systemically administered anti-sclerostin antibodies (Anti-Scl Ab) on orthodontic tooth movements (OTM) in an ovariectomized rat.

Methods: Twenty-four 12-week-old female Sprague-Dawley rats were randomly divided into two groups: (1) ovariectomy (OVX) group, (2) ovariectomy + romosozumab (ROMO) group. OTM was performed 8 weeks after OVX.

View Article and Find Full Text PDF

Enhanced dual-mode imaging: Superior photoacoustic and ultrasound endoscopy in live pigs using a transparent ultrasound transducer.

Sci Adv

November 2024

Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Device Innovation Center, Pohang University of Science and Technology (POSTECH), Pohang 37673, Republic of Korea.

Dual-mode photoacoustic/ultrasound endoscopy (ePAUS) is a promising tool for preclinical and clinical interventions. To be clinically useful, ePAUS must deliver high-performance ultrasound imaging comparable to commercial systems and maintain high photoacoustic imaging performance at long working distances. This requires a transducer with an intact physical aperture and coaxial alignment of acoustic and optical beams within the probe, a challenging integration task.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!