Background: Transcatheter aortic valve implantation (TAVI) is a treatment option for high-risk patients with severe aortic stenosis. Previous reports focused on a single device or access site, whereas little is known of the combined use of different devices and access sites as selected by the heart team. The purpose of this study is to investigate clinical outcomes of TAVI using different devices and access sites.
Methods: A consecutive cohort of 200 patients underwent TAVI with the Medtronic CoreValve Revalving system (Medtronic Core Valve LLC, Irvine, CA; n = 130) or the Edwards SAPIEN valve (Edwards Lifesciences LLC, Irvine, CA; n = 70) implanted by either the transfemoral or transapical access route.
Results: Device success and procedure success were 99% and 95%, respectively, without differences between devices and access site. All-cause mortality was 7.5% at 30 days, with no differences between valve types or access sites. Using multivariable analysis, low body mass index (<20 kg/m(2)) (odds ratio [OR] 6.6, 95% CI 1.5-29.5) and previous stroke (OR 4.4, 95% CI 1.2-16.8) were independent risk factors for short-term mortality. The VARC-defined combined safety end point occurred in 18% of patients and was driven by major access site complications (8.0%), life-threatening bleeding (8.5%) or severe renal failure (4.5%). Transapical access emerged as independent predictor of adverse outcome for the Valve Academic Research Consortium-combined safety end point (OR 3.3, 95% CI 1.5-7.1).
Conclusion: A heart team-based selection of devices and access site among patients undergoing TAVI resulted in high device and procedural success. Low body mass index and history of previous stroke were independent predictors of mortality. Transapical access emerged as a risk factor for the Valve Academic Research Consortium-combined safety end point.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ahj.2011.01.025 | DOI Listing |
Arch Orthop Trauma Surg
January 2025
Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.
Patients with unstable hemodynamics and unstable pelvic ring injuries are still demanding patients regarding initial treatment and survival. Several concepts were reported during the last 30 years. Mechanical stabilization of the pelvis together with hemorrhage control offer the best treatment option in these patients.
View Article and Find Full Text PDFCVIR Endovasc
January 2025
Department of Radiology, Section of Vascular and Interventional Radiology, University of Washington, 1959 Northeast Pacific Street, Seattle, WA, 98195, USA.
Purpose: To evaluate access site adverse events following ClotTriever-mediated large-bore mechanical thrombectomy via small upper extremity deep veins (< 6-mm).
Materials And Methods: Twenty patients, including 24 upper extremity venous access sites, underwent ClotTriever-mediated large-bore thrombectomy of the upper extremity and thoracic central veins for symptomatic deep vein obstruction unresponsive to anticoagulation. Patients without follow-up venous duplex examinations (n = 3) were excluded.
Angew Chem Int Ed Engl
January 2025
University of Fribourg Faculty of Science: Universite de Fribourg Faculte de sciences et de medecine, Adolphe Merkle Institue, Chemin des Verdiers 4, 1700, Fribourg, SWITZERLAND.
Metal halide perovskites have shown exceptional potential in converting solar energy to electric power in photovoltaics, yet their application is hampered by limited operational stability. This stimulated the development of hybrid layered (two-dimensional, 2D) halide perovskites based on hydrophobic organic spacers, templating perovskite slabs, as a more stable alternative. However, conventional organic spacer cations are electronically insulating, resulting in charge confinement within the inorganic slabs, thus limiting their functionality.
View Article and Find Full Text PDFIntegr Cancer Ther
January 2025
University of Las Palmas de Gran Canaria (ULPGC), Las Palmas de Gran Canaria, Spain.
Background: Numbness and tingling secondary to chemotherapy-induced peripheral neuropathy (CIPN) are frequent side effects that limit chemotherapy treatment and quality of life. Successful treatments for CIPN are limited. This preliminary report shows the potential long-term effects of ozone treatment in the management of persistent numbness and tingling secondary to CIPN.
View Article and Find Full Text PDFJ Clin Med
December 2024
Herzzentrum Dresden, Department of Internal Medicine and Cardiology, Technische Universität Dresden, Fetscherstr. 76, 01307 Dresden, Germany.
Patients with end-stage kidney disease (ESRD) represent a high-risk population in terms of both development of and death by cardiovascular diseases. Outcome data of ESRD patients with severe aortic valve stenosis (AS) treated by transcatheter aortic valve implantation (AVI) are scarce. We aim to compare the outcome of ESRD patients undergoing transfemoral (TF) or transapical (TA) AVI.