Bioprosthesis valve replacement in dogs with congenital tricuspid valve dysplasia: technique and outcome.

J Vet Cardiol

Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO 80523-1678, USA.

Published: June 2011

Objective: To describe the surgical technique and report outcome of dogs undergoing bioprosthesis valve replacement for severe tricuspid regurgitation (TR) secondary to congenital tricuspid valve dysplasia (TVD).

Animals, Materials And Methods: Twelve client-owned dogs (19-43 kg) with TVD underwent tricuspid valve replacement with a bovine pericardial or porcine aortic bioprosthesis with the aid of cardiopulmonary bypass. Anticoagulation with warfarin was maintained for 3 months after surgery and then discontinued.

Results: Ten of 12 (83.3%) dogs survived surgery and were discharged from the hospital. Seven dogs were alive with complete resolution of TR for a median period of 48 months (range 1-66 months) after surgery. Two dogs underwent euthanasia because of bioprosthesis failure due to inflammatory pannus at 10 and 13 months after surgery. Two dogs experienced valve thrombosis that was resolved by tissue plasminogen activator. One dog developed suspected endocarditis after surgery that was resolved with antibiotics. Serious cardiac complications included atrial fibrillation and flutter, right-to-left shunt through an uncorrected patent foramen ovale, complete atrioventricular block, and sudden cardiac arrest. Postoperative atrial fibrillation or flutter did not occur in 7 dogs treated prophylactically with oral amiodarone before surgery.

Conclusions: Curative intermediate-term outcomes are possible in dogs undergoing open tricuspid valve replacement with a bioprosthesis. Prosthesis-related complications include inflammatory pannus, thrombosis, and endocarditis. Postoperative atrial fibrillation or flutter can be reduced or prevented by prophylactic preoperative treatment with amiodarone. Several identified complications are avoidable or can be reduced with increased awareness and experience with these techniques.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvc.2010.12.002DOI Listing

Publication Analysis

Top Keywords

valve replacement
16
tricuspid valve
16
months surgery
12
atrial fibrillation
12
fibrillation flutter
12
dogs
9
bioprosthesis valve
8
congenital tricuspid
8
valve dysplasia
8
dogs undergoing
8

Similar Publications

Transcatheter versus Surgical Aortic Valve Replacement in Patients Younger than 65 Years in the US.

J Thorac Cardiovasc Surg

January 2025

Department of Cardiac Surgery, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA. Electronic address:

Objective: To characterize trends and outcomes of aortic valve replacement in patients <65 with aortic stenosis between 2013 and 2021.

Methods: This retrospective analysis included 9,557 patients who underwent biological aortic valve replacement in California, New York, and New Jersey from 2013 through 2021. Patients were stratified by approach: transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR).

View Article and Find Full Text PDF

Aortic valve leaflet assessment to inform novel bioinspired materials: Understanding the impact of collagen fibres on the tissue's mechanical behaviour.

J Mech Behav Biomed Mater

December 2024

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, 2, Dublin, Ireland; Discipline of Mechanical, Manufacturing, and Biomedical Engineering, School of Engineering, Trinity College Dublin, 2, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Ireland. Electronic address:

Aortic stenosis is a prevalent disease that is treated with either mechanical or bioprosthetic valve replacement devices. However, these implants can experience problems with either functionality in the case of mechanical valves or long-term durability in the case of bioprosthetic valves. To enhance next generation prosthetic valves, such as biomimetic polymeric valves, an improved understanding of the native aortic valve leaflet structure and mechanical response is required to provide much needed benchmarks for future device development.

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on the outcomes of aortic valve replacement (AVR) in young Moroccan patients with severe aortic regurgitation and impaired left ventricle function.
  • A total of 42 out of 110 patients with significant aortic regurgitation and an ejection fraction of ≤35% underwent AVR, showing a low immediate postoperative mortality rate of 4.7%.
  • Long-term follow-up indicated a high survival rate of 86.8% after 15 years, along with significant clinical improvements and increased left ventricle ejection fraction post-surgery.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!