Objectives: The hypothesis of the study was that the incidence of pin loosening and pin infection would increase, whereas the general stability of the pin-bone interface would decrease with ongoing implantation time. The aim of this study was to analyze the biologic reactions of the bone tissue adjacent to the pin to determine the relationship among the osseous anchorage of pins, the incidence of infections, and the histologic appearance.

Methods: Three groups of sheep received a tibial osteotomy stabilized by external fixators. The pin-bone interface was analyzed biomechanically, radiologically, microbiologically, and histologically after 3, 6, and 9 weeks.

Results/conclusions: Contrary to common opinion, pin anchorage was not altered biomechanically throughout the 9 weeks of the study. This effect might be attributed to an increasing remodeling found in the callus and cortex around the pins and was likely assisted by a strict pin care routine and a low infection rate.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0b013e3181ecf856DOI Listing

Publication Analysis

Top Keywords

pin-bone interface
12
pin
5
interface external
4
external fixator
4
fixator standardized
4
standardized analysis
4
analysis sheep
4
sheep osteotomy
4
osteotomy model
4
model objectives
4

Similar Publications

Unilateral external fixator and its biomechanical effects in treating different types of femoral fracture: A finite element study with experimental validated model.

Heliyon

February 2024

Bone Biomechanics Laboratory (BBL), Department of Biomedical Engineering and Health Sciences, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru, 81310, Johor, Malaysia.

Previous works had successfully demonstrated the clinical effectiveness of unilateral external fixator in treating various types of fracture, ranging from the simple type, such as oblique and transverse fractures, to complex fractures. However, literature that investigated its biomechanical analyses to further justify its efficacy is limited. Therefore, this paper aimed to analyse the stability of unilateral external fixator for treating different types of fracture, including the simple oblique, AO32C3 comminuted, and 20 mm gap transverse fracture.

View Article and Find Full Text PDF

A practical definition of pin site infection.

Injury

February 2024

Bone Infection Unit, Nuffield Orthopaedic Centre, Oxford University Hospitals, Oxford, United Kingdom of Great Britain and Northern Ireland, UK. Electronic address:

Pin Site Infection (PSI) is the most common complication of external fixation treatment. Several classifications and diagnostic approaches have been used with reported incidences varying widely from 1 to 100 %. The quality of the existing literature is limited by the absence of a definition.

View Article and Find Full Text PDF

Monolateral pin-to-bar-clamp fixators are commonly used to stabilize acute extremity injuries. Certain rules regarding frame geometry have been established that affect construct stability. The influence of sagittal pin angulation on construct stiffness and strength has not been investigated.

View Article and Find Full Text PDF

The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective.

Injury

August 2021

Bioinpired Devices and Tissue Engineering (BIOINSPIRA) Research Group, School of Biomedical Engineering and Health Sciences, Faculty of Engineering, Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor, Malaysia; Sports Innovation and Technology Centre (SITC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor, Malaysia. Electronic address:

An external fixator is a promising medical device that could provide optimum stability and reduce the rate of complications in treating bone fracture during intervention period. It is noted that the biomechanics behaviour of device can be altered by introducing more features such as material suitability and additional components. Therefore, this study was conducted via finite element method to investigate the effects of additional hollow cylinder coated with external fixator screws in treating Type III pilon fracture.

View Article and Find Full Text PDF

Osteoporosis and osteoarthritis are common pathological problems of the human bone tissue. There are some cases of pilon fractures associated with these 2 pathological conditions. In terms of treatment, for a normal and healthy bone with pilon fracture, the use of the Delta external fixator is a favorable option because it can allow early mobilization for patients and provide stability for the healing process.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!