In this paper, the application of "parallel" moiré deflectometry in measuring the nonlinear refractive index of materials is reported. In "parallel" moiré deflectometry the grating vectors are parallel, and the resulting moiré fringes are also parallel to the grating lines. Compared to "rotational" moiré deflectometry and the Z-scan technique, which cannot easily determine the moiré fringe's angle of rotation and is sensitive to power fluctuations, respectively, "parallel" moiré deflectometry is more reliable, which allows one to measure the radius of curvature of the light beam by measuring the moiré fringe spacing. The nonlinear refractive index of the sample, including the sense of the change, is obtained from the moiré fringe spacing curve. The method is applied for measuring the nonlinear refractive index of ferrofluids.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.50.002356DOI Listing

Publication Analysis

Top Keywords

moiré deflectometry
20
"parallel" moiré
16
nonlinear refractive
16
moiré
9
application "parallel"
8
z-scan technique
8
measuring nonlinear
8
moiré fringe
8
fringe spacing
8
deflectometry
5

Similar Publications

Improving Industrial Quality Control: A Transfer Learning Approach to Surface Defect Detection.

Sensors (Basel)

January 2025

Centre of Mechanical Technology and Automation (TEMA), Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal.

To automate the quality control of painted surfaces of heating devices, an automatic defect detection and classification system was developed by combining deflectometry and bright light-based illumination on the image acquisition, deep learning models for the classification of non-defective (OK) and defective (NOK) surfaces that fused dual-modal information at the decision level, and an online network for information dispatching and visualization. Three decision-making algorithms were tested for implementation: a new model built and trained from scratch and transfer learning of pre-trained networks (ResNet-50 and Inception V3). The results revealed that the two illumination modes employed widened the type of defects that could be identified with this system, while maintaining its lower computational complexity by performing multi-modal fusion at the decision level.

View Article and Find Full Text PDF

We present an experimental investigation of the formation stage of a collisionless shock when the flow velocity is aligned with an ambient magnetic field utilizing laser-driven, super-Alfvénic plasma flows. As the flows interact, electromagnetic streaming instabilities develop. Proton deflectometry is used to visualize these electromagnetic fluctuations indicating the development of the ion-Weibel instability and the nonresonant instability.

View Article and Find Full Text PDF

Stereo Bi-Telecentric Phase-Measuring Deflectometry.

Sensors (Basel)

September 2024

State Key Laboratory of Precision Measuring Technology and Instruments, Laboratory of Micro/Nano Manufacturing Technology, Tianjin University, Tianjin 300072, China.

Replacing the endocentric lenses in traditional Phase-Measuring Deflectometry (PMD) with bi-telecentric lenses can reduce the number of parameters to be optimized during the calibration process, which can effectively increase both measurement precision and efficiency. Consequently, the low distortion characteristics of bi-telecentric PMD contribute to improved measurement accuracy. However, the calibration of the extrinsic parameters of bi-telecentric lenses requires the help of a micro-positioning stage.

View Article and Find Full Text PDF

Proton deflectometry is used in magnetized high-energy-density plasmas to observe electromagnetic fields. We describe a reconstruction algorithm to recover the electromagnetic fields from proton fluence data in 1-D. The algorithm is verified against analytic solutions and applied to example data.

View Article and Find Full Text PDF

Based on the polynomial theory, the error propagation characteristics of the widely used N-step discrete Fourier transform (N-DFT) phase-shift algorithm were analyzed via theoretical analysis, under the effect of Gamma distortion and phase detuning. The results showed that the N-DFT algorithm could not simultaneously suppress both types of error. A robust linear phase-shift (RLPS) algorithm was designed, the performance of the RLPS and 8-DFT algorithms in terms of spectral response, detuning robustness, and was briefly analysis by Manuel Servin method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!