GPU-based iterative cone-beam CT reconstruction using tight frame regularization.

Phys Med Biol

Center for Advanced Radiotherapy Technologies, University of California, San Diego, La Jolla, CA 92037-0843, USA.

Published: July 2011

The x-ray imaging dose from serial cone-beam computed tomography (CBCT) scans raises a clinical concern in most image-guided radiation therapy procedures. It is the goal of this paper to develop a fast graphic processing unit (GPU)-based algorithm to reconstruct high-quality CBCT images from undersampled and noisy projection data so as to lower the imaging dose. For this purpose, we have developed an iterative tight-frame (TF)-based CBCT reconstruction algorithm. A condition that a real CBCT image has a sparse representation under a TF basis is imposed in the iteration process as regularization to the solution. To speed up the computation, a multi-grid method is employed. Our GPU implementation has achieved high computational efficiency and a CBCT image of resolution 512 × 512 × 70 can be reconstructed in ∼5 min. We have tested our algorithm on a digital NCAT phantom and a physical Catphan phantom. It is found that our TF-based algorithm is able to reconstruct CBCT in the context of undersampling and low mAs levels. We have also quantitatively analyzed the reconstructed CBCT image quality in terms of the modulation-transfer function and contrast-to-noise ratio under various scanning conditions. The results confirm the high CBCT image quality obtained from our TF algorithm. Moreover, our algorithm has also been validated in a real clinical context using a head-and-neck patient case. Comparisons of the developed TF algorithm and the current state-of-the-art TV algorithm have also been made in various cases studied in terms of reconstructed image quality and computation efficiency.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/56/13/004DOI Listing

Publication Analysis

Top Keywords

cbct image
16
image quality
12
imaging dose
8
cbct
8
algorithm
8
algorithm reconstruct
8
image
5
gpu-based iterative
4
iterative cone-beam
4
cone-beam reconstruction
4

Similar Publications

Effect of initial bone morphology on alveolar bone remodeling following molar extraction: A retrospective study.

J Periodontol

January 2025

Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, China.

Background: The clinical evidence about alveolar ridge changes following molar extraction and how the alveolar bone morphology influences the ridge dimensional changes remains limited.

Methods: A total of 192 patients with 199 molar extractions were included in this retrospective study. Cone-beam computed tomography (CBCT) images of patients were obtained 0-3 months pre extraction and 6-12 months post extraction.

View Article and Find Full Text PDF

In image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with sufficient quality requires significantly more projection images than a standard 3D-CBCT scan, leading to extended scanning times and increased imaging dose to the patient. To address these limitations, there is a strong demand for methods capable of reconstructing high-quality 4D-CBCT images from a 1-minute 3D-CBCT acquisition.

View Article and Find Full Text PDF

Background: Histotripsy is a non-invasive, non-ionizing, non-thermal focused ultrasound technique. High amplitude short acoustic pulses converge to create high negative pressures that cavitate endogenous gas into a bubble cloud leading to mechanical tissue destruction. In the United States, histotripsy is approved to treat liver tumors under diagnostic ultrasound guidance but in initial clinical cases, some areas of the liver have not been treated due to bone or gas obstructing the acoustic window for targeting.

View Article and Find Full Text PDF

Negotiation of the intricate pulp canal space may pose a challenge in endodontic treatment. Consequently, appropriate diagnosis and thorough knowledge of the pattern and distribution of root canal systems are imperative for a more predictable outcome in the treatment of pulp diseases. Accordingly, cone beam computed tomography (CBCT) is deemed appropriate as an adjunctive diagnostic tool in endodontics.

View Article and Find Full Text PDF

A platform combining automatic segmentation and automatic measurement of the maxillary sinus and adjacent structures.

Clin Oral Investig

January 2025

State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, 610041, China.

Objectives: To develop a platform including a deep convolutional neural network (DCNN) for automatic segmentation of the maxillary sinus (MS) and adjacent structures, and automatic algorithms for measuring 3-dimensional (3D) clinical parameters.

Materials And Methods: 175 CBCTs containing 242 MS were used as the training, validating and testing datasets at the ratio of 7:1:2. The datasets contained healthy MS and MS with mild (2-4 mm), moderate (4-10 mm) and severe (10- mm) mucosal thickening.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!