A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of different operation modes of high performance liquid chromatography for the analysis of complex mixtures of neutral oligosaccharides. | LitMetric

Chromatographic methods based on different HPLC operation modes, reverse phase (RP), high performance anion exchange chromatography (HPAEC), graphitized carbon chromatography (GCC) and hydrophilic interaction liquid chromatography (HILIC), have been developed and compared for the analysis of complex mixtures of neutral oligosaccharides with functional properties. Whereas GCC gave the best chromatographic separation of isomeric oligosaccharides with the same molecular weight (R(s) values in the range 1.0-4.0 and 2.4-5.6 for tetra- and pentasaccharides, respectively), HILIC provided the best results for mixtures including oligosaccharides of different degrees of polymerization (R(s) values of maltooligosaccharides between 3.4 and 6.2). Validation of the HILIC LC-MS method proved its utility for the analysis of oligosaccharide mixtures with functional properties: relative standard deviations lower than 10%, LOD's and LOQ's in the range 12.7-130.2 ng mL(-1) and 39.3-402.2 ng mL(-1), respectively, and linearity up to 10-20 μg mL(-1). Quantitative data for fructooligosaccharides, gentiooligosaccharides and dextransucrase cellobiose acceptor oligosaccharides were obtained by using this method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2011.05.015DOI Listing

Publication Analysis

Top Keywords

operation modes
8
high performance
8
liquid chromatography
8
analysis complex
8
complex mixtures
8
mixtures neutral
8
neutral oligosaccharides
8
functional properties
8
oligosaccharides
5
evaluation operation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!