State of the art in hard-on-hard bearings: how did we get here and what have we achieved?

Expert Rev Med Devices

Division of Orthopaedic Surgery, University of Toronto, 100 College Street Room 302, Toronto, Ontario M5G 1L5, Canada.

Published: March 2011

Total hip arthroplasty has shown excellent results in decreasing pain and improving function in patients with degenerative disease of the hip. Improvements in prosthetic materials, designs and implant fixation have now resulted in wear of the bearing surface being the limitation of this technology, and a number of hard-on-hard couples have been introduced to address this concern. The purpose of this article is to review the origins, development, survival rates and potential advantages and disadvantages of the following hard-on-hard bearings for total hip arthroplasty: metal-on-metal standard total hip arthroplasty; metal-on-metal hip resurfacing arthroplasty, ceramic-on-ceramic total hip arthroplasty; and ceramic-on-metal bearings. Improvements in the manufacturing of metal-on-metal bearings over the past 50 years have resulted in implants that provide low wear rates and allow for the use of large femoral heads. However, concerns remain regarding elevated serum metal ion levels, potential teratogenic effects and potentially devastating adverse local tissue reactions, whose incidence and pathogenesis remains unclear. Modern total hip resurfacing has shown excellent outcomes over 10 years in the hands of experienced surgeons. Current ceramic-on-ceramic bearings have demonstrated excellent survival with exceptionally low wear rates and virtually no local adverse effects. Concerns remain for insertional chipping, in vivo fracture and the variable incidence of squeaking. Contemporary ceramic-on-metal interfaces are in the early stages of clinical use, with little data reported to date. Hard-on-hard bearings for total hip arthroplasty have improved dramatically over the past 50 years. As bearing designs continue to improve with new and modified materials and improved manufacturing techniques, it is likely that the use of hard-on-hard bearings will continue to increase, especially in young and active patients.

Download full-text PDF

Source
http://dx.doi.org/10.1586/erd.10.75DOI Listing

Publication Analysis

Top Keywords

total hip
24
hip arthroplasty
20
hard-on-hard bearings
16
hip
8
bearings total
8
arthroplasty metal-on-metal
8
hip resurfacing
8
low wear
8
wear rates
8
concerns remain
8

Similar Publications

Background: Intraoperative hip capsule management is increasingly recognized as an important component of hip arthroscopy for the prevention of capsular-related instability. The periportal capsulotomy, relative to the interportal capsulotomy, has been proposed as a minimally invasive technique for decreasing postarthroscopy hip instability; however, the biomechanical effects of this technique are not well established.

Purpose/hypothesis: This study aimed to provide a biomechanical characterization of interportal and periportal capsulotomies, helping inform surgeon choice of capsulotomy type and repair, potentially guiding clinical practice in hip arthroscopy.

View Article and Find Full Text PDF

Bone mineral density (BMD) levels achieved on osteoporosis treatment are predictive of subsequent fracture risk, and T-score > -2.5 has been proposed as a minimum treatment target for women with osteoporosis. Knowing the likelihood of attaining target T-scores with different medications for different baseline BMD levels can help determine appropriate initial treatment for individual patients.

View Article and Find Full Text PDF

IntroductionTraditional obesity measures including body mass index, waist circumference, waist-to-hip ratio, and waist-to-height ratio have limitations. The primary objective of this study was to identify and review the validity of non-traditional obesity measures, using measures of total body fat as the reference standard, that have been used across multiple life stages. MethodsWe conducted a systematic review and searched MEDLINE, Embase, and PsycINFO.

View Article and Find Full Text PDF

Parkinson's disease (PD) is characterized by a slow, short-stepping, shuffling gait pattern caused by a combination of motor control limitations due to a reduction in dopaminergic neurons. Gait disorders are indicators of global health, cognitive status, and risk of falls and increase with disease progression. Therefore, the use of quantitative information on the gait mechanisms of PD patients is a promising approach, particularly for monitoring gait disorders and potentially informing therapeutic interventions, though it is not yet a well-established tool for early diagnosis or direct assessment of disease progression.

View Article and Find Full Text PDF

Pseudotumors are defined as exuberant non-neoplastic inflammatory masses. This condition can be associated with hip and knee arthroplasty but has not been reported in Total Ankle Arthroplasty (TAA). This paper reports a pseudotumor that formed following TAA, highlighting its clinical presentation, management, and histopathology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!