Background: At present, only some studies have dealt with immediate loading of unsplinted implants supporting mandibular overdentures. The aim of this prospective study is to evaluate treatment outcomes of mandibular overdentures supported by four one-piece, unsplinted, immediately loaded, direct laser metal-forming (DLMF) implants by assessing implant survival rate, implant success, marginal bone loss, and prosthetic complications.
Methods: A total of 96 one-piece DLMF implants were inserted in the edentulous mandible of 24 patients. Four implants were placed in each edentulous mandible. Immediately after implant placement, a mandibular overdenture was connected to the implants. At 1-year follow-up, clinical, radiographic, and prosthetic parameters were assessed. Success criteria included absence of pain, suppuration, and implant mobility; absence of continuous peri-implant radiolucency; and distance between the implant shoulder and the first visible bone contact <1.5 mm.
Results: After a 1-year loading time, the overall implant survival rate was 98.9%, with only one implant lost. Among the surviving 95 implants, two did not fulfill the success criteria; therefore, the implant success rate was 97.8%. The mean distance between the implant shoulder and the first visible bone contact was 0.28 ± 0.30 mm (95% confidence interval, 0.24 to 0.32). Some prosthetic complications were reported.
Conclusion: Based on the present results and within the limits of this study, the immediate loading of four unsplinted DLMF implants by means of ball attachment-supported mandibular overdentures seems to represent a safe and successful procedure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1902/jop.2011.110079 | DOI Listing |
BMC Oral Health
January 2025
Removable Prosthodontics Department, Faculty of Dentistry, October 6 University, Giza, Egypt.
Background: The continuous development in digital prosthodontics allowed the customization of attachments and retentive inserts which offers an easy and cheap solution for regular maintenance of locator overdentures during daily practice. The present study compared the change in retention values of the fully digitally manufactured custom-made locator attachment retentive insert with the ready-made ones after insertion, removal, and masticatory cycles.
Methods: A complete denture was constructed over a mandibular edentulous epoxy model.
Materials (Basel)
January 2025
Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain.
Sandblasting and acid etching are common procedures used to treat implant surfaces, enhancing osseointegration and improving clinical success rates. This clinical study aimed to evaluate the long-term outcomes of sandblasted and acid-etched implants. A total of 303 implants were placed in 114 partially and totally edentulous patients using a two-stage surgical technique and an early loading protocol (6-8 weeks).
View Article and Find Full Text PDFInt J Implant Dent
January 2025
Lecturer at removable prosthodontic department, Faculty of dental medicine for Girls, Al-Azhar University, Cairo, Egypt.
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics, K M Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).
Setting And Design: In vitro (in silico study) finite element analysis (FEA).
Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.
Dent Mater J
December 2024
Mechanical Engineering, Faculty of Engineering, Atatürk University.
This study aimed to apply finite element analysis (FEA) to simulate the oral environment of a patient with an implant-supported overdenture prosthesis. A 3D mandibular model was created for a 45-year-old female patient from CT images, with mucosal thickness measured at 3 mm on average using ultrasonography. The overdenture prosthesis was scanned with an intraoral scanner and placed onto the 3D mandibular model.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!