Objectives: To establish an education and training programme for the reduction of CT radiation doses and to assess this programme's efficacy.
Methods: Ten radiological institutes were counselled. The optimisation programme included a small group workshop and a lecture on radiation dose reduction strategies. The radiation dose used for five CT protocols (paranasal sinuses, brain, chest, pulmonary angiography and abdomen) was assessed using the dose-length product (DLP) before and after the optimisation programme. The mean DLP values were compared with national diagnostic reference levels (DRLs).
Results: The average reduction of the DLP after optimisation was 37% for the sinuses (180 vs. 113 mGycm, P < 0.001), 9% for the brain (982 vs. 896 mGycm, P < 0.05), 24% for the chest (425 vs. 322 mGycm, P < 0.05) and 42% for the pulmonary arteries (352 vs. 203 mGycm, P < 0.001). No significant change in DLP was found for abdominal CT. The post-optimisation DLP values of the sinuses, brain, chest, pulmonary arteries and abdomen were 68%, 10%, 20%, 55% and 15% below the DRL, respectively.
Conclusions: The education and training programme for radiological institutes is effective in achieving a substantial reduction in CT radiation dose.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-011-2168-5 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!